Safety of new algorithms for premeal insulin boluses in high glycaemic index meals in persons with type 1 diabetes mellitus using insulin pumps.

Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub

Department of Physiology, 2nd Department of Medicine, Faculty of Medicine and Dentistry, Palacký University, Olomouc, Czech Republic.

Published: June 2008

Aims: Consumption of glucose or foodstuffs with high glycaemic index (GI) in persons with type 1 diabetes mellitus (PWD1) is a hot topic in present diabetology. The aim of our pilot prospective study was to assess the efficiency of empirically suggested simple algorithms for premeal boluses in PWD1 using insulin pumps and continuous glucose monitoring (CGM).

Methods: Six PWD1 (aged 46.2+/-15.09 y, diabetes duration 14.5+/-9.65 y, HbA1c/IFCC 6.3+/-1.59%, BMI 23.6+/-1.67 kg/m(2), mean+/-SD) on insulin pumps Paradigm 522/722 with RT-CGMS sensors (Medtronic MiniMed, Northridge, CA) underwent a 12-week CGM. In one week, subjects consumed 50 g of carbohydrates in eleven alternative meals (rice squares, dark chocolate, white bread, honey, glucose, ravioli with meat and Eidam cheese, mashed potatoes with fish fingers, apricot dumplings with butter, spa waffles, spalta squares, and tomato soup with pasta) eaten for breakfasts, lunches, snacks and dinners in order to calculate their GI. The insulin boluses were adjusted according to empirically defined algorithms. Average glucose levels and daily insulin doses over three one-week periods (before testing, testing and after testing) were compared.

Results: During the observational period, the weekly averages of glucose levels (9.1+/-2.33 mmol/l vs. 9.2+/-2.30 mmol/l vs. 9.0+/-2.43 mmol/l, respectively) and daily insulin doses (39.1+/- 8.14 IU/d vs. 39.7+/-10.7 IU/d vs. 38.6+/-9.97 IU/d, respectively) were similar. One-week consumption of high GI foodstuffs had only a negligeable effect on average glucose levels.

Conclusion: The suggested algorithms for premeal insulin boluses appear to limit the risk of potential hyperglycaemia resulting from intake of high GI foodstuffs.

Download full-text PDF

Source
http://dx.doi.org/10.5507/bp.2008.011DOI Listing

Publication Analysis

Top Keywords

algorithms premeal
12
insulin boluses
12
insulin pumps
12
insulin
8
premeal insulin
8
high glycaemic
8
persons type
8
type diabetes
8
diabetes mellitus
8
average glucose
8

Similar Publications

Carbohydrate counting (CC) and meal announcements, before eating, introduce a significant burden for individuals managing type 1 diabetes (T1D). An automated insulin delivery system with automatic bolusing that eliminates the need for CC and premeal bolusing (i.e.

View Article and Find Full Text PDF

Automated insulin delivery systems: from early research to routine care of type 1 diabetes.

Acta Diabetol

February 2023

Department of Endocrinology, Diabetes, Nutrition, Montpellier University Hospital, Montpellier, France.

Automated insulin delivery (AID) systems, so-called closed-loop systems or artificial pancreas, are based upon the concept of insulin supply driven by blood glucose levels and their variations according to body glucose needs, glucose intakes and insulin action. They include a continuous glucose monitoring device which provides a signal to a control algorithm tuning insulin delivery from an infusion pump. The control algorithm is the key of the system since it commands insulin administration in order to maintain blood glucose in a predefined target range and close to a near-normal glucose level.

View Article and Find Full Text PDF

We recently reported that use of an "advanced" hybrid closed-loop system reduced hyperglycemia without increasing hypoglycemia compared to a first-generation system. The aim of this analysis was to evaluate whether this improved performance was specifically related to better mealtime glycemic control. We conducted a secondary analysis of postprandial glycemic control in an open-label, multinational, randomized crossover trial of 112 participants with type 1 diabetes, aged 14-29, of the Medtronic MiniMed™ 670G hybrid closed-loop system (670G) versus the Medtronic advanced hybrid closed-loop (AHCL) system, for 12 weeks each.

View Article and Find Full Text PDF

Background: Artificial pancreas design using subcutaneous insulin infusion without pre-meal feed-forward boluses often induces an over-response leading to hypoglycemia due to the increase of blood insulin concentration sustained in time. The objective of this work was to create an algorithm for controlling the function of insulin pumps in closed-loop systems to improve blood glucose management in type 1 diabetic patients by mimicking the pulsatile behaviour of the pancreas.

Methods: A controller tuned in a pulsatile way promotes damped oscillations of blood insulin concentration injected through an insulin pump.

View Article and Find Full Text PDF

: Diabetes may affect in-hospital mortality of patients with Coronavirus disease 2019 (COVID-19). We have retrospectively evaluated clinical characteristics, diabetes management, and outcomes in a sample of COVID-19 patients with diabetes admitted to our hospital. : All patients admitted to the Infectious Diseases Unit from 28 March 2020, to 16 June 2020, were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!