Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1057
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3175
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To examine the effect of 4 commercially available contact lens multipurpose solutions (MPS) on the viability and barrier function of human corneal epithelial cells in vitro.
Methods: Immortalized human corneal epithelial cells were exposed to 4 solutions, MPS A, B, C, and D with culture medium and Hanks' Balanced Salt Solution as controls. MTT assay was used to evaluate cell viability. ApopTag Fluorescein Apoptosis assay was used to detect cell death in situ. Corneal epithelial barrier function was evaluated by fluorescein permeability and immunofluorescent staining for tight junction proteins zonula occludens (ZO)-1 and occludin.
Results: Corneal epithelial survival rates, evaluated by MTT assay showed no statistical difference between MPS A and the culture medium or Hanks' Balanced Salt Solution controls. MPS B, C, and D were associated with significantly less cell survival than the controls after exposure for 6 hrs (all P<0.01). Compared with the controls, the MPS A did not increase cell apoptosis, whereas the other 3 caused higher apoptotic rates. The epithelial permeability after exposure to MPS A was similar to controls and significantly lower than MPS B and MPS D (P<0.01). The tight junction proteins ZO-1 and occludin were well maintained after exposure to MPS A. In contrast, the expression of ZO-1 and occludin were largely disturbed by the other 3 MPS solutions.
Conclusions: The current marketed contact lens MPS may have negative effects on human corneal epithelial viability and barrier function. Among 4 MPS studied, MPS A maintains the cell viability and barrier function significantly better than other 3 marketed products.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8313347 | PMC |
http://dx.doi.org/10.1097/ICL.0b013e3181842518 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!