A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determination of gallium in human urine by supercritical carbon dioxide extraction and graphite furnace atomic absorption spectrometry. | LitMetric

Determination of gallium in human urine by supercritical carbon dioxide extraction and graphite furnace atomic absorption spectrometry.

J Hazard Mater

Institute of Occupational Safety and Hazard Prevention, Hungkuang University, Shalu, Taichung 433, Taiwan, ROC.

Published: April 2009

This study presents supercritical carbon dioxide (scCO(2)) extraction as an inherently safer and cleaner sample treatment method for identifying trace gallium in urine samples. Extraction is performed in the presence of a fluorinated beta-diketones chelating agent, 2,2-dimethyl-6,6,7,7,8,8,8-heptafluoro-3,5-octanedione (HFOD), by unmodified scCO(2). Quantitative extractions are conducted at 80 degrees C and 20.7 MPa with 15 min static plus 15 min dynamic extractions, and are followed by analysis via graphite furnace atomic absorption spectroscopy (GFAAS). The proposed procedure is successfully applied to determine the concentrations of gallium in real urine samples spiked with various levels of gallium with satisfactory recoveries of 90.8-100.3% (n=6) and relative standard deviations <10%. A standard reference material (SRM), Seronorm Trace Elements Urine, is used to validate the accuracy of the proposed method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2008.07.093DOI Listing

Publication Analysis

Top Keywords

supercritical carbon
8
carbon dioxide
8
graphite furnace
8
furnace atomic
8
atomic absorption
8
urine samples
8
determination gallium
4
gallium human
4
human urine
4
urine supercritical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!