A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of two-dimensional and three-dimensional systems for kinematic analysis of the sagittal motion of canine hind limbs during walking. | LitMetric

Comparison of two-dimensional and three-dimensional systems for kinematic analysis of the sagittal motion of canine hind limbs during walking.

Am J Vet Res

Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Purdue University, West Lafayette, IN 47907, USA.

Published: September 2008

Objective: To test the hypotheses that kinematic data of the sagittal motion of canine hind limbs during walking obtained with a 2-dimensional (2-D) system correlate well with those obtained with a 3-dimensional (3-D) system and that the data obtained with the 2-D system are repeatable.

Animals: 6 adult dogs with no evidence of lameness.

Procedures: Hind limb motions of 6 walking dogs were recorded via 2-D video and 3-D optoelectric systems simultaneously. Five valid trials were digitized, and 5 data sets (2-D 60 Hz, 3-D 180 Hz, 3-D sagittal 180 Hz, 3-D 60 Hz, and 3-D sagittal 60 Hz) of a complete gait cycle were created for each dog. In sagittal data sets, 3-D data were reduced to exclude coordinates for mediolateral orientation. Temporospatial parameters; angles of hip, stifle, and tarsal joints; and coefficients of variation of angular measurements of each dog were calculated for each data set. Accuracy of the 2-D analysis was determined by calculating mean absolute differences and estimating agreement between the 2-D and 3-D 180-Hz data sets.

Results: Values of joint angles and angular excursions measured with the 2-D system were repeatable and agreed with respective values obtained with the 3-D system. Reduction of the sampling rate had a greater impact on values of kinematic variables obtained with the 3-D system than did elimination of data on mediolateral orientation.

Conclusions And Clinical Relevance: Kinematic analysis using a 2-D video system provided accurate and repeatable data of the sagittal angular motion of canine hind limbs during walking.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.69.9.1116DOI Listing

Publication Analysis

Top Keywords

motion canine
12
canine hind
12
hind limbs
12
limbs walking
12
2-d system
12
3-d system
12
3-d
10
data
9
kinematic analysis
8
sagittal motion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!