A simple, cost-effective analysis combining solventless extraction, thermal desorption, and determination of volatile organic compounds (VOCs) was developed and validated. A needle trap device (NTD) packed with the sorbent Carboxen1000 was used as a time-weighted average (TWA) diffusive sampler to collect target compounds by molecular diffusion and adsorption to the packed sorbent. This process can be described with derivations of Fick's first law of diffusion, which expresses the relation between the TWA concentrations to which the passive sampler is exposed and the mass of analytes adsorbed to the packed sorbent in the sampler. The effects of experimental factors such as temperature, pressure, humidity, and face velocity were taken into account in applying diffusive sampling under nonideal conditions. This study demonstrates that NTD is effective for air analysis of benzene, toluene, ethylbenzene, and o-xylene (BTEX), due to the good adsorption/desorption quality of Carboxen 1000 and to the special geometric shape of the needle with a small cross section avoiding the need for calibration. Storage tests showed good storage stability for BTEX. Verification of the theoretical model showed good agreement between theoretical and experimental sampling rates. Method validation done against NIOSH method 1501, SPME, and NTD active sampling revealed good agreement between those methods. Automated NTD sample introduction to a gas chromatograph facilitates the use of this technology for industrial hygiene applications.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac800884fDOI Listing

Publication Analysis

Top Keywords

packed sorbent
12
needle trap
8
trap device
8
time-weighted average
8
diffusive sampling
8
good agreement
8
development application
4
application needle
4
device time-weighted
4
average diffusive
4

Similar Publications

Mycotoxins are detectable in 60-80% of food crops, posing significant threats to human health and food security, and causing substantial economic losses. Most mitigation approaches focus on detecting mycotoxins with standard methods based on liquid chromatography coupled with mass spectrometry (LC-MS). Typical MS methods require extensive sample preparation and clean-up due to the matrix effect, followed by time-consuming LC separation, complicating the analysis process and limiting analytical throughput.

View Article and Find Full Text PDF

Separation of high-activity Bi from Ac for targeted alpha therapy is challenging due to the instability of existing sorbents. Surface-modified carbon materials have shown promise for use in inverse Ac/Bi generators. However, previously reported materials with irregular shapes may limit their applications in column separations.

View Article and Find Full Text PDF

In this study, an automatic magnetic solid phase extraction method was developed to determine six parent neonicotinoids (NEOs) and three of their metabolites in breast milk, serum and urine samples. As key extraction parameters, the sorbent amount, washing solvent and elution solvent were optimized to 4 mg of HLB packing magnetic sorbent, pure water and acetonitrile, respectively. Recoveries of the analytes ranged between 81% and 121% for bovine milk samples, 64% and 122% for fetal bovine serum samples and 81% and 109% for pooled urine samples, with RSDs of <20%.

View Article and Find Full Text PDF

Munition constituents (MC) in stormwater runoff have the potential to move these pollutants into receiving bodies at military installations. Here we present further evaluation of a passive and sustainable biofilter technology for removal of dissolved MC from simulated surface runoff by combined sorption-biodegradation processes under dynamic flow conditions. Columns were packed with MC sorbents Sphagnum peat moss and cationized (CAT) pine shavings with and without wood-based biochar.

View Article and Find Full Text PDF

This study presents a comprehensive comparison between the packed bed and monolith contactor configurations for direct air capture (DAC) via process modeling of a temperature-vacuum swing adsorption (TVSA) process. We investigate various design parameters to optimize performance across different contactor geometries, including pellet size, monolith wall thickness, active sorbent content in monoliths, and packed bed structure configurations, considering both a traditional long column (PB) and multiple shorter columns configured in parallel (PB). Our parametric analysis assesses specific exergy consumption, sorbent, and volume requirements across different operating conditions of a five-step TVSA cycle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!