Purpose: The Integrated Abutment Crown (IAC) is a technique for the fabrication of single-tooth implant-supported crowns where the abutment and the crown are one unit. The abutment-crown complex is connected to the implant with a locking taper. This technique does not use cement to retain the crown or screws to retain the abutment. The purpose of this study was to evaluate the clinical outcome of screwless, cementless single implant-supported crowns (IACs) placed in a general dental practice.

Materials And Methods: A retrospective cohort study was conducted between July 2001 and August 2003. Patients were recalled between January and March 2004. The restorations were evaluated following the modified United States Public Health Service (USPHS) criteria. Several other variables, such as anatomic form, occlusion, soft tissue health, and reconstructive procedures, were also recorded. Descriptive statistics, univariate and multivariate marginal Cox Proportional Hazards Regression models, adjusted for multiple implants in the same patient, were used.

Results: During the chart review, 108 patients were identified. A cohort of 59 patients with a total of 151 IACs met the inclusion criteria. The Kaplan-Meier survival rate for IACs was 98.7%. Two IACs were removed, one due to implant failure; the other became loose several times and was replaced with a splinted restoration. Excellent marginal adaptation was observed with no clinically discernible interface between the veneer material and the abutment. Nine maxillary anterior IACs loosened on five patients; eight of them were reinserted and continued in function without further problems for the remainder of the study. An IAC located between a tooth and an implant was 2.65 times more likely to have postinsertion complications (p= 0.05). An IAC with incorrect anatomic form (overcontoured) was 3.26 times more likely to have postinsertion complications (p= 0.01). Maxillary anterior IACs adjacent to one tooth and one implant were 3.9 times more likely to come loose (p= 0.05).

Conclusions: The clinical outcome of this screwless and cementless system for single implant restorations compares favorably with the experience of screw- and cement-retained single implant restorations within the observation period.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1532-849X.2008.00343.xDOI Listing

Publication Analysis

Top Keywords

screwless cementless
12
retrospective cohort
8
cohort study
8
abutment crown
8
implant-supported crowns
8
clinical outcome
8
outcome screwless
8
anatomic form
8
maxillary anterior
8
anterior iacs
8

Similar Publications

Background: Uncemented press-fit acetabular cups without screws rely on the elastic recoil of the bone for its primary stability and tend to leave polar gaps with its use. The clinical significance of these gaps and the functional outcome of the patients with polar gaps is evaluated in this study.

Methods: This comparative analysis was done on 224 cementless primary THA using Deltamotion® Hip System from January 2010 to December 2017.

View Article and Find Full Text PDF

Guided Nitinol-Retained (Smileloc) Single-Tooth Dental Restorations.

Oral Maxillofac Surg Clin North Am

August 2019

Santa Cruz Oral & Maxillofacial Surgery, 1663 Dominican Way, Suite 112, Santa Cruz, CA 95065, USA.

Nitinol metal alloy that changes shape according to temperature has been in clinical use at select clinics worldwide for the past 2 years and is now released for general use. The Smileloc Abutment and nitinol sleeve enable "cementless," "screwless," crown fastening that saves time and cost with the prospect of replacement of much of the present, sometimes troublesome, anthropic, soon to be anachronistic, technology.

View Article and Find Full Text PDF

In a randomized prospective study, we compared the use of tibial screws with screwless tibial baseplate fixation in uncemented total knee arthroplasty and report the results of 154 prostheses at a mean follow-up of 5 years. Patients were mobilized within 24 hours and continued with partial weight-bearing for up to 6 weeks postoperatively. There were no significant differences in radiologic results and revision rates.

View Article and Find Full Text PDF

This study compared two groups of consecutive patients undergoing total knee arthroplasty (TKA) with an identical cementless tibial baseplate supplementally fixated with and without screws. In 58 TKAs, two 6.5-mm cancellous screws were used for fixation, and in 58 TKAs, screwless fixation was used.

View Article and Find Full Text PDF

Purpose: The Integrated Abutment Crown (IAC) is a technique for the fabrication of single-tooth implant-supported crowns where the abutment and the crown are one unit. The abutment-crown complex is connected to the implant with a locking taper. This technique does not use cement to retain the crown or screws to retain the abutment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!