Background: Assessment of volume status is vital for successful management of patients in heart failure (HF) programs. Bedside determination of elevated left-sided filling pressure (LFP) can be challenging and frequently inaccurate; therefore, incorporating technology such as handheld echocardiography, to aid in estimation of LFP, may improve patient care. In this study, we evaluated the feasibility and accuracy of handheld echocardiography by a nonexpert for potential use in the point of care evaluation of compensation.
Methods: Subjects were recruited from the HF clinic or inpatient service at a single center. Each subject underwent a focused handheld transthoracic echocardiogram by a medical resident trained for 10 hours. Subjects were assigned to 1 of 4 filling patterns (1 = normal, 2 = abnormal relaxation, 3 = pseudonormal, 4 = restrictive) based on measurements by pulsed wave and tissue Doppler. A 3-step echocardiography test for congestion in HF (TEC-HF) was devised for estimation of LFP. The gold standard for determining elevated LFP was clinical evaluation by a HF specialist, who classified subjects as being euvolemic or hypervolemic.
Results: A total of 100 consecutive subjects (72% male) were recruited, with average age of 60 years and left ventricular ejection fraction of 27%. All subjects had evaluable echocardiographic data. Based on TEC-HF, filling patterns 3 and 4 predicted hypervolemia and patterns 1 and 2 predicted euvolemia, with sensitivity and specificity of 86% and 92%, respectively, and positive and negative predictive values of 86% and 92%, respectively.
Conclusions: Applying TEC-HF with handheld echocardiography accurately reflects clinical LFP as assessed by HF specialists. This procedure was easily taught to nonexpert medical staff who obtained adequate images in all patients. Handheld echocardiography could be a useful tool for assessing volume status in nonspecialized community settings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ahj.2008.04.015 | DOI Listing |
Crit Care
January 2025
División de Terapia Intensiva, Hospital Juan A. Fernández, Buenos Aires, Argentina.
The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
December 2024
Cardiology, Hospital Universitario Marqués de Valdecilla, IDIVAL, University of Cantabria, Santander, Spain.
Hand-held ultrasound devices (HHUD) are increasingly used in routine clinical practice, though they lacked continuous (CW) Doppler capability until recent times. There is limited evidence on the utility of HHUD in assessing aortic stenosis (AS) in real-world settings. Our goal was to validate a new HHUD with CW Doppler assessing AS hemodynamic severity.
View Article and Find Full Text PDFBMJ Open
October 2024
Menzies School of Health Research, Charles Darwin University, Darwin, Northern Territory, Australia
Introduction: Rheumatic heart disease (RHD) is underdiagnosed globally resulting in missed treatment opportunities and adverse clinical outcomes. We describe the protocol for a study which aims to co-design, implement and conduct an evaluation of a task-sharing approach to echocardiographic active case finding for early detection and management of RHD in high-risk settings in Australia and Timor-Leste.
Methods And Analysis: Echocardiograms will be obtained by trained local staff using hand-held echocardiographic devices employing the 'Single Parasternal Long Axis view with a Sweep of the Heart' (SPLASH) technique and interpreted by experts remote from the site of acquisition.
J Med Ultrasound
August 2024
Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands.
Background: Reliable quantification of stroke volume (SV) and left ventricular ejection fraction (LVEF) is essential for point-of-care assessment in hemodynamically compromised patients. Handheld echocardiography (HHE) equipment has entered the market a few years ago and is now available for clinical use. However, the performance of HHE for SV and LVEF quantification in comparison to cardiac magnetic resonance (CMR) imaging as golden standard is yet unknown.
View Article and Find Full Text PDFIEEE Trans Ultrason Ferroelectr Freq Control
October 2024
A sparse array offers a significant reduction in the complexity of ultrasonic imaging systems by decreasing the number of active elements and associated electrical circuits needed to form a focused beam. Consequently, for 1-D arrays, it has been adopted in the development of miniaturized systems such as portable, handheld, or smartphone-based systems. Previously, we developed an analytic method that can design a pair of 1-D periodic sparse arrays (PSAs) satisfying three specific constraints, which are the array size, desired grating lobe level, and sparseness factor (SF).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!