Access site complications are major source of morbidity following cardiac catheterization. Their incidence varies in the literature because of multiple definitions and methods of determining the presence of particular complication. The aim of this prospective study was to determine the incidence of access site complications following cardiac catheterization using arterial duplex ultrasonography. A total of 319 consecutive patients, who had cardiac catheterization underwent femoral artery duplex study 24 to 48 hours following manual hemostasis. Diagnostic angiogram had 232 (71.8%) while 87 (28.2%) had percutaneous coronary intervention (PCI). Femoral artery duplex ultrasound was normal in 247 (77.4%). Haematoma was found in 48 (15.1%), pseudoaneurysm in 17 (5.3%), AV fistula in 2 (0.6%) and dissection of the femoral artery in 5 (1.6%) patients. Baseline demografic characteristics were similar in group with normal duplex study and group with detected complication. Pseudoaneurysm and AV fistula were more commonly observed in patients following PCI than diagnostic angiogram (9.2% vs. 4.7%, p<0.001). Patients with documented complications more frequently had concomitant administration of antiplatelet and anticoagulant medication compared to the patients without complications (p=0.003). Hemodynamic disturbances (hypotension and bradycardia) during manual compression were more frequent in patients with complication (11% vs. 4.5%, p=0.047). Low threshold for use of duplex ultrasound should be exercised in patients following cardiac catheterization to establish the presence of access site complications. Special attention is needed in the setting of aggressive antiplatelet and anticoagulant therapy, interventional procedures and hemodynamic disturbances during manual hemostas.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cardiac catheterization
16
access site
12
site complications
12
femoral artery
12
complications cardiac
8
duplex ultrasonography
8
artery duplex
8
duplex study
8
diagnostic angiogram
8
duplex
5

Similar Publications

Background Rapid treatment of ST-elevation myocardial infarction (STEMI) patients with primary percutaneous coronary intervention (PCI) significantly reduces morbidity and mortality rates. Recent studies emphasize the importance of reducing total ischemic time, making first-medical-contact-to-balloon (FMCTB) time a key performance indicator. To improve FMCTB times in patients brought to the Emergency Department (ED) by Emergency Medical Services (EMS), we implemented a "Direct to Lab" (DTL) workflow during the following conditions: weekday daytime hours, when the lab is fully staffed, and for hemodynamically stable STEMI patients presenting via EMS.

View Article and Find Full Text PDF

Dual phase multidetector computed tomography angiography in evaluation of pulmonary arteries and collateral vessels in children with cyanotic congenital heart diseases.

Med J Armed Forces India

December 2024

National Manager-Health System Strengthening, United Nations Development Program (UNDP), 55 Lodhi Estate, New Delhi, India.

Background: The purpose of this paper is to compare the efficacy of dual-phase multidetector computed tomography angiography (CTA) with transthoracic echocardiogram (TTE) and cardiac catheterization angiography (CCA) in evaluation of pulmonary arteries and collateral vessels, major aortopulmonary collateral arteries (MAPCAs) in children with cyanotic congenital heart diseases.

Methods: The study was a prospective observational study where 32 pediatric patients (18 males, 14 females and age range 2-116 months) with cyanotic congenital heart diseases (CCHD) were included. All patients underwent TTE, CTA, and CCA.

View Article and Find Full Text PDF

Device endothelialization and morphology assessments at 1 year using computed tomography angiography: comparison of traditional with novel puncturable atrial septal defect occluders.

BMC Cardiovasc Disord

December 2024

Department of Cardiology, Zhongshan Hospital, Fudan University, National Clinical Research Center for Interventional Medicine, Shanghai Institute of Cardiovascular Diseases, 180 Fenglin Road, Xuhui District, Shanghai, 200032, China.

Background: Complete endothelialization is often not achieved within 6 months after implantation of an atrial septal defect (ASD) occluder, which may lead to microthrombus or thrombosis. This study aimed to assess the endothelialization and morphology of a novel puncturable ASD occluder (ReAces) compared with traditional occluders 1 year post-implantation using computed tomography angiography (CTA).

Methods: Fifteen patients from each group in a randomized controlled trial comparing ReAces with traditional occluders were included at the 1-year follow-up at Zhongshan Hospital, Fudan University.

View Article and Find Full Text PDF

Right ventricular reserve in cardiopulmonary disease: a simultaneous hemodynamic and three-dimensional echocardiographic study.

J Heart Lung Transplant

December 2024

Department of Cardiology, Ospedale San Luca IRCCS Istituto Auxologico Italiano, Milano, Italy; Department of Management, Information and Production Engineering, University of Bergamo, Dalmine (BG), Italy.

Background: RV reserve has been linked to exercise capacity and prognosis in cardiopulmonary diseases. However, evidence in this setting is limited, due to the complex shape and load dependency of the RV. We sought to study right ventricular (RV) adaptation to exercise by simultaneous three-dimensional echocardiography (3DE) and right heart catheterization (RHC).

View Article and Find Full Text PDF

Extended Rhythm Monitoring to Assess for Ventricular Arrhythmias After Transcatheter Pulmonary Valve Replacement With the Harmony Valve.

Circ Cardiovasc Interv

December 2024

Department of Pediatrics, Pediatric Cardiology, Stanford University, Palo Alto, CA. (J.K.Y., L.W., A.C.T., H.C., A.W.R., L.F.P., S.R.C., A.M.D., D.B.M.).

Background: Varying rates of nonsustained ventricular tachycardia (NSVT) have been reported early after transcatheter pulmonary valve replacement (TPVR) with the Harmony valve, but data regarding rhythm outcomes beyond hospital discharge are limited. This study aims to characterize ventricular arrhythmias after Harmony TPVR from implant through mid-term follow-up.

Methods: Ventricular arrhythmia data from postimplant telemetry and follow-up extended rhythm monitoring (ERM) were analyzed after Harmony TPVR.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!