A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionsk5rubp3nnd5cnk3k9rgmf7hcmio9f52): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A 4-mm needle reduces the risk of intramuscular injections without increasing backflow to skin surface in lean diabetic children and adults. | LitMetric

Download full-text PDF

Source
http://dx.doi.org/10.2337/dc08-0977DOI Listing

Publication Analysis

Top Keywords

4-mm needle
4
needle reduces
4
reduces risk
4
risk intramuscular
4
intramuscular injections
4
injections increasing
4
increasing backflow
4
backflow skin
4
skin surface
4
surface lean
4

Similar Publications

Background: Transthoracic biopsy has proven to be an effective procedure, especially for peripheral lung lesions, in obtaining samples that can definitively diagnose the underlying pathology. Despite its effectiveness, studies have demonstrated that it is associated with complications such as pneumothorax and hemoptysis. This study aims to evaluate the incidence of these complications and identify prognostic factors in patients who underwent a transthoracic biopsy.

View Article and Find Full Text PDF

Objectives: Basilic vein transposition (BVT) surgery is a crucial option for vascular access in hemodialysis patients when other alternatives are unavailable. One of the primary complications affecting the long-term function of arteriovenous fistulas (AVFs) is the development of pseudoaneurysms, often caused by repeated punctures at the same site. This study aims to evaluate whether increasing the length of the basilic vein available for cannulation during the second stage of BVT surgery reduces the risk of puncture-related pseudoaneurysms, thereby improving fistula longevity and functionality.

View Article and Find Full Text PDF

Introduction: Mild-to-moderate blepharoptosis can be aesthetically displeasing for patients, particularly in cases involving a single eyelid. However, certain patients are reluctant to undergo surgical intervention. Botulinum neurotoxin A (BoNT-A) injection offers a potential solution in such cases.

View Article and Find Full Text PDF

Objective: To assess the diagnostic success rate and complications of computed tomography (CT)-guided percutaneous biopsy in pulmonary nodules < 10 mm in diameter.

Materials And Methods: This was a retrospective, single-center study involving the review of medical records, images, and chest CT reports related to 115 patients who underwent percutaneous CT-guided biopsy of < 10 mm pulmonary nodules between July 2015 and January 2019.

Results: Nodule diameter on the longest axis ranged from 4 mm to 9 mm, with a mean size of 7.

View Article and Find Full Text PDF
Article Synopsis
  • - The study aimed to identify errors in transrectal ultrasound (TRUS)-based reconstructions for high-dose-rate brachytherapy in prostate cancer, using an electromagnetic tracking (EMT) system to enhance accuracy during treatment.
  • - Out of 265 evaluated needle reconstructions, 23% had minor errors or worse, with 9% classified as major or severe, primarily due to issues like incorrect needle placement and user errors.
  • - The findings indicate that one-quarter of the reconstructions had errors exceeding 2mm, highlighting the potential of EMT to help detect and prevent these mistakes, improving patient care without affecting the clinical process.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!