Fast joint reconstruction of dynamic R2* and field maps in functional MRI.

IEEE Trans Med Imaging

Department of Electrical Engineering and ComputerScience, The University of Michigan, 2360 Bonisteel Blvd., Ann Arbor, MI48109 USA.

Published: September 2008

Blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) is conventionally done by reconstructing T(2)(*)-weighted images. However, since the images are unitless they are nonquantifiable in terms of important physiological parameters. An alternative approach is to reconstruct R(2)(*) maps which are quantifiable and have comparable BOLD contrast as T(2)(*)-weighted images. However, conventional R(2)(*) mapping involves long readouts and ignores relaxation during readout. Another problem with fMRI imaging is temporal drift/fluctuations in off-resonance. Conventionally, a field map is collected at the start of the fMRI study to correct for off-resonance, ignoring any temporal changes. Here, we propose a new fast regularized iterative algorithm that jointly reconstructs R(2)(*) and field maps for all time frames in fMRI data. To accelerate the algorithm we linearize the MR signal model, enabling the use of fast regularized iterative reconstruction methods. The regularizer was designed to account for the different resolution properties of both R(2)(*) and field maps and provide uniform spatial resolution. For fMRI data with the same temporal frame rate as data collected for T(2)(*)-weighted imaging the resulting R(2)(*) maps performed comparably to T(2)(*)-weighted images in activation detection while also correcting for spatially global and local temporal changes in off-resonance.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2008.917247DOI Listing

Publication Analysis

Top Keywords

r2* field
12
field maps
12
t2*-weighted images
12
r2* maps
8
temporal changes
8
fast regularized
8
regularized iterative
8
fmri data
8
r2*
6
maps
5

Similar Publications

Cancer remains a leading cause of mortality, with aggressive, treatment-resistant tumors posing significant challenges. Current combination therapies and imaging approaches often fail due to disparate pharmacokinetics and difficulties correlating drug delivery with therapeutic response. In this study, we developed radionuclide-activatable theranostic nanoparticles (NPs) comprising folate receptor-targeted bimetallic organo-nanoparticles (Gd-Ti-FA-TA NPs).

View Article and Find Full Text PDF

Molecular dynamics (MD) simulations are an important and well-established tool for investigating RNA structural dynamics, but their accuracy relies heavily on the quality of the employed force field (). In this work, we present a comprehensive evaluation of widely used pair-additive and polarizable RNA s using the challenging UUCG tetraloop (TL) benchmark system. Extensive standard MD simulations, initiated from the NMR structure of the 14-mer UUCG TL, revealed that most s did not maintain the native state, instead favoring alternative loop conformations.

View Article and Find Full Text PDF

Soundscape studies vary considerably in study design, statistical methods, and model fit metrics used. Due to this confounding of data and methods, it is difficult to assess the suitability of statistical modelling techniques used in the literature. Therefore, five different methods and two performance metrics were applied to three existing soundscape datasets to model soundscape Pleasantness and Eventfulness based on seven acoustic and three sociodemographic predictors.

View Article and Find Full Text PDF

Purpose: Due to the extensive use of radiation in various fields, such as food safety, sterilizing surgical materials, and medical diagnostics, it is essential to minimize radiation exposure for both patients and healthcare professionals, even at low doses. To meet this requirement, a composite film has been developed using polyvinyl alcohol (PVA) polymer and nitro blue tetrazolium (NBT) dye to measure low radiation doses effectively.

Methods: Various concentrations of NBT dye (ranging from 0.

View Article and Find Full Text PDF

Photonic crystal-based aptasensors for viral proteins detection offer the advantage of producing visible readouts. However, they usually suffer from limited sensitivity and high non-specific background noise. A significant contributing factor to these issues is the use of fixed-conformation aptamers in these sensors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!