Background And Objective: Lack of adherence to inhaled corticosteroid therapy is common in patients with asthma, and it has been suggested that allowing patients to choose their own inhalers would resolve this problem. The FSI-10 (Feeling of Satisfaction with Inhaler) is a self-completed questionnaire to assess patient opinions regarding ease or difficulty of use, portability, and usability of devices for delivery of inhaled corticosteroids. The aim of this study was to define the measurement properties of the FSI-10 questionnaire and to use this inventory to compare satisfaction and preferences of patients with asthma regarding 3 different devices for delivery of inhaled corticosteroids: Turbuhaler, Accuhaler, and Novolizer.
Patients And Methods: We performed a multicenter, prospective, observational study in 112 stable asthmatic patients (64 women; mean [SD] age, 37 [22] years) treated on a regular basis with inhaled corticosteroids. The use of the devices was explained to the patients and the order in which they should be used in each case was randomly assigned. The devices were used for 7-day periods and at the end of each the FSI-10 questionnaire was completed for the device used. Once the protocol was completed, patients stated their preference for the different devices used.
Results: The FSI-10 was easily understood and rapidly completed, and it exhibited acceptable measurement properties. Factor analysis showed that the measure was unidimensional. Although acceptance of all 3 devices assessed was reasonable, the FSI-10 questionnaire detected significant differences between them: Turbuhaler and Novolizer scored higher than Accuhaler on a number of questions. This preference is partly explained by Turbuhaler having been the device that was commonly used by the patients prior to the study. However, the highest scoring and most often preferred inhaler in patients under 16 years of age was the Novolizer, even though the Turbuhaler had also usually been used by those patients prior to the study.
Conclusions: The FSI-10 is a useful instrument for assessing the degree of satisfaction of asthmatic patients regarding available inhalation devices. It is easy to understand and complete, and able to identify differences in patient satisfaction with the different inhalers.
Download full-text PDF |
Source |
---|
Allergy
December 2024
Department of Pulmonary Medicine, AmsterdamUMC, University of Amsterdam, Amsterdam, The Netherlands.
Background: Long-acting beta2-agonists (LABA) in combination with inhaled corticosteroids (ICS) are commonly used to treat asthma, however, some children lack response to the addition of LABA. This might be partially due to the presence of the Arg16Gly polymorphism, encoded by rs1042713 G>A in the ADRB2 gene. Carrying the A allele (Arg16) at this variant has been associated with an increased risk of exacerbations despite LABA treatment.
View Article and Find Full Text PDFBackground: Whether inhaled corticosteroids (ICSs) reduce major adverse cardiovascular events (MACEs) in people with chronic obstructive pulmonary disease (COPD) is debated.
Objectives: To establish, within people with COPD, (1) whether ICS reduced MACE rates (acute coronary syndrome (ACS), heart failure (HF), ischaemic strokes or cardiovascular-specific death) compared with long-acting bronchodilators; and (2) whether drug class, incident usership or patient cardiovascular history influenced the ICS-MACE relationship.
Methods: We conducted a cohort study including patients with COPD in England, using Clinical Practice Research Datalink Aurum data, linked with Hospital Episode Statistics and Office of National Statistics death data, between 1 January 2010 and 31 December 2019.
Cureus
November 2024
Department of Multidisciplinary Internal Medicine, Division of Respiratory Medicine and Rheumatology, School of Medicine, Faculty of Medicine, Tottori University, Tottori, JPN.
A saber-sheath trachea is a type of tracheal deformity characterized by coronal narrowing and sagittal widening of the intrathoracic trachea. In this case report, we describe a 76-year-old man with a history of chronic obstructive pulmonary disease (COPD) and repeated episodes of type 2 respiratory failure that responded poorly to inhaled long-acting β2 agonists, long-acting muscarinic antagonists, and corticosteroids. The patient was admitted to our hospital due to a COPD exacerbation.
View Article and Find Full Text PDFCureus
November 2024
Department of Pulmonary Medicine, King's College Hospital, Dubai, ARE.
Middle Eastern countries, such as the United Arab Emirates and Oman, are affected by frequent dust storms and extreme hot climatic conditions, which can exacerbate respiratory conditions. These environmental factors are particularly injurious to asthmatic patients, as they can aggravate small airway disease (SAD), leading to increased morbidity and healthcare challenges. The evaluation of maximal mid-expiratory flow (MEF-25) as a diagnostic and therapeutic tool for early-stage small airway dysfunction is of significant clinical importance, particularly in hot and arid metropolitan environments where dusty conditions exacerbate pulmonary issues.
View Article and Find Full Text PDFAdv Ther
December 2024
US Value Evidence and Outcomes, GSK, Collegeville, PA, USA.
Introduction: The clinical benefits of fluticasone furoate/umeclidinium/vilanterol (FF/UMEC/VI) have been demonstrated in clinical trials. There is limited evidence regarding the effectiveness and economic outcomes associated with FF/UMEC/VI use in US clinical practice. This real-world study assessed asthma-related exacerbations, healthcare resource utilization (HRU), and healthcare costs among a Medicare Advantage-insured population before and after initiation of FF/UMEC/VI in patients with asthma previously treated with an inhaled corticosteroid/long-acting β-agonist (ICS/LABA).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!