13C-methionine breath test has been proposed as a non-invasive tool for the assessment of human hepatic mithocondrial function. Two methionine breath labeled with 13C in differents point of his molecular structure have been used for breath test analisys. Aim of this study was to compare two differently 13C-labeled methionines in the evaluation of mitochondrial oxidation in basal conditions and after an acute oxidative stress. 15 healthy male subjects (mean age 30.5 +/- 3.1) received [methyl-13C]-methionine dissolved in water. Breath samples were taken at baseline and and 10, 20, 30, 45, 60, 75, 90, 105 and 120 minutes after the ingestion of the labeled substrate. Forthy-eight hours later, subjects underwent the same test 30 minutes after ethanol ingestion (0,3 g/kg of body weight). Seven-day later, subjects underwent breath test using (L-methionine-1-13COOH) as substrate, in basal condition and after ethanol ingestion. At basal condition, the cumulative percentage of 13CO2 recovered in breath during the test period (%cum-dose) was higher using L-methionine-1-13COOH than [methyl-13C]-methionine (10.25 +/- 1.0 vs 4.07 +/- 0.8; p < 0.01). After ethanol ingestion, % cum dose was significantly decreased at 60 and 120 minutes with both methionines (120 min: 10.25 +/- 1.0 vs 5.03% +/- 1.8; < 0.01 and 4.07 +/- 0.8 vs 2.16% +/- 0.9; p < 0.01, respectively). However, %cum-dose during L-methionine-1-13C-breath test was significantly lower than that observed during methyl-13C-methionine breath test (120 minutes: 5.03% +/- 1.8 vs 2.16% +/- 0.9; p < 0.01). In conclusion, breath test based on L-methionine-1-13COOH seems to show a greater reliability when compared to [methyl-13C]-methionine to assess mitochondrial function because a larger amount of labeled carbon that reaches the Krebs' cicle.

Download full-text PDF

Source

Publication Analysis

Top Keywords

breath test
24
+/- 001
16
120 minutes
12
ethanol ingestion
12
+/-
9
13c-methionine breath
8
breath
8
test
8
subjects underwent
8
basal condition
8

Similar Publications

Free-Breathing Respiratory Triggered High-Pitch Lung CT: Insights From Phantom and Patient Scans.

Invest Radiol

January 2025

From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).

Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.

View Article and Find Full Text PDF

Exhalation of Rn-219 by patients treated with Radium-223.

EJNMMI Phys

January 2025

Department for Radiation Protection and Medical Physics, Hannover Medical School, Carl-Neuberg- Str. 1, 30625, Hannover, Germany.

Background: Treatment with Ra-223 dichloride is approved for the therapy of castration resistant prostate cancer (CRPC) with symptomatic bone metastases and no known visceral metastases in Europe since 2013, and Ra-223 is under discussion for labelling other molecules and nanoparticles. The direct progeny of Ra-223 is Rn-219, also known as actinon, a radioactive noble gas with a half-life of 3.98 s.

View Article and Find Full Text PDF

This review emphasises the importance of the cardiovascular response to facial cooling (FC) and breath holding in both sexes. The trigemino-cardiac reflex, triggered by FC, reduces heart rate (HR) and constricts blood vessels. When combined with breath holding, this effect intensifies, enhancing the cardiodepressive impact.

View Article and Find Full Text PDF

Background And Aims: Hematopoietic stem cell transplantation (HSCT) is a key therapeutic approach for pediatric patients with hematologic and non-hematologic disorders. However, post-transplant pulmonary complications remain a significant cause of morbidity and mortality. Pulmonary Function Tests (PFTs) are essential for the early detection of pulmonary dysfunction, yet their application in pediatric HSCT recipients has yielded inconsistent results.

View Article and Find Full Text PDF

Massive Pulmonary Embolism With Negative D-dimer: A Case Report.

Cureus

December 2024

Nursing & Midwifery Research, Hamad Medical Corporation, Doha, QAT.

Pulmonary embolism (PE) is a critical condition that arises when clots migrate to the lungs, obstructing pulmonary circulation and posing a significant risk to the patient's health. While the D-dimer test is useful for excluding PE, it is not infallible. This report describes a case where extensive PE was present despite the patient having a normal D-dimer level, emphasizing the importance of a thorough clinical evaluation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!