Drug-eluting stents (DES) have made a tremendous impact on the practice of percutaneous coronary intervention. Recently however, long-term DES failures have become a focal point, particularly with restenosis and thrombosis. An uncommon, yet important cause of DES failure is stent fracture. Of the two established first generation DES, the sirolimus-eluting stent (SES) has been particularly linked to cases of stent fracture, likely as a result of its closed cell design compared with other DES employing an open cell system. We present 2 cases of SES fracture confirmed using high-resolution intravascular optical coherence tomography giving unique insights into the in-vivo appearance of this complication.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2008.04.076 | DOI Listing |
Cureus
November 2024
Urology, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Dr. D. Y. Patil Vidyapeeth (Deemed to be University) Pune, Pune, IND.
Urethrovaginal fistulas are rare complications often arising from urethrovaginal injuries commonly due to obstetrical trauma, urethral surgeries, pelvic fractures, or neoplastic treatments. Here, we present a unique case involving a 23-year-old female patient with a large urethrovaginal fistula and complete anterior vaginal wall sloughing following prolonged obstructed labor. Nine months post-cesarean, she reported urine leakage via the vagina upon catheter removal, which intensified in an erect posture.
View Article and Find Full Text PDFJ Endovasc Ther
December 2024
Institute for Vascular Research, St. Franziskus Hospital, Münster, Germany.
Background: To compare the performance of a new-generation cobalt-chromium balloon-expandable bare metal stent with a stainless steel platform for the treatment of iliac occlusive disease.
Methods: Consecutive patients treated for symptomatic iliac occlusive disease between 2014 and 2021 with the cobalt-chromium Dynetic-35 or the stainless steel Dynamic platform were retrospectively evaluated. Outcome measures included technical success, device- or procedure-related death, clinically-driven target lesion revascularization (CD-TLR), primary patency, and major index limb amputation up to 12 months.
Ophthalmic Plast Reconstr Surg
December 2024
Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine.
Purpose: The purpose of this study was to evaluate the clinical features, surgical treatments, and outcomes of pediatric post-traumatic nasolacrimal duct obstructions and predictors for surgical outcomes.
Methods: A retrospective chart review was performed of patients under the age of 18 years with the diagnosis of traumatic nasolacrimal duct obstructions during an 11-year period from a tertiary referral center. The clinical data were reviewed and analyzed.
J Stroke Cerebrovasc Dis
December 2024
Department of Neurosurgery, Nagoya University of Graduate School of Medicine, Nagoya, Japan. Electronic address:
Objectives: Vascular Eagle syndrome (ES) is a rare condition involving vessel compression by an elongated styloid process, leading to neurologic symptoms. Here, we present the case of a patient with a complication of carotid artery stenting for vascular ES and discuss the implications of treatment of this rare condition.
Case Description: A 35-year-old previously healthy male patient presented with transient aphasia and right-sided hemiparesis following ischemic stroke in left frontal lobe.
Photodiagnosis Photodyn Ther
December 2024
Department of Nuclear Medicine, Akdeniz University Faculty of Medicine, Antalya, Turkey.
Purpose: To assess the anatomical and functional outcomes in patients who underwent surgery for canalicular laceration and did not experience significant epiphora, and to compare these outcomes with contralateral uninjured eye.
Method: Dacryoscintigraphy, anterior segment optical coherence tomography (OCT), MUNK scores, and a satisfaction questionnaire were administered to 24 patients who had canalicular laceration repair without significant epiphora and had a minimum of 6 months of follow-up. Tear meniscus height (TMH), depth (TMD), and area (TMA) were measured using anterior segment OCT and compared with the values in the uninjured eye.