Comparison of analytical techniques for the determination of aldehydes in test chambers.

Chemosphere

Fraunhofer Wilhelm-Klauditz-Institute (WKI), Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig, Germany.

Published: November 2008

The level of carbonyl compounds in indoor air is crucial due to possible health effects and the high prevalence of their potential sources. Therefore, selecting a convenient and rapid analytical technique for the reliable detection of carbonyl compound concentrations is important. The acetyl acetone (acac) method is a widely used standard procedure for detecting gaseous formaldehyde. For measuring formaldehyde along with other carbonyl compounds, the DNPH-method is commonly applied. The recommended procedure for measuring volatile organic compounds (VOCs) is sampling on Tenax TA, followed by thermal desorption and GC/MS analysis. In this study, different analytical techniques for the quantification of formaldehyde, pentanal, and hexanal are critically compared. It was found that the acac- and DNPH-method are in very good agreement for formaldehyde. In contrast, the DNPH-method significantly underestimates indoor air concentrations of the higher aldehydes in comparison to sampling on Tenax TA, although both methods are strongly correlated. The reported results are part of the EURIMA-WKI study on levels of indoor air pollutants resulting from construction, building materials and interior decoration.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chemosphere.2008.06.054DOI Listing

Publication Analysis

Top Keywords

indoor air
12
analytical techniques
8
carbonyl compounds
8
sampling tenax
8
comparison analytical
4
techniques determination
4
determination aldehydes
4
aldehydes test
4
test chambers
4
chambers level
4

Similar Publications

Effect of air temperature in indoor transition spaces on the thermal response of occupant during summer.

Sci Rep

January 2025

Innovation Institute for Sustainable Maritime Architecture Research and Technology, Qingdao University of Technology, Qingdao, 266033, People's Republic of China.

During the hot summer months, the significant temperature disparity between outdoor and indoor air-conditioned spaces can lead to thermal discomfort and pose a potential health risk. Transition areas such as corridors and elevator lobbies, serving as intermediary zones connecting indoors and outdoors, have been found effective in mitigating this thermal discomfort. In this study, three different temperatures (25 °C-case 1, 27 °C-case 2, and 29 °C-case 3) were employed to investigate the dynamic physiological regulation and thermal perception response of individuals when transitioning from an outdoor environment into an indoor neutral room through a transition space.

View Article and Find Full Text PDF

Introduction: Although evidence exists on the impact of microbiota on pregnancy outcomes in many high-resource settings, there is a lack of research in many low-resource settings like Ethiopia. This study aims to fill this gap by studying the gut and vaginal microbiota changes throughout pregnancy and assess how these changes relate to pregnancy outcomes among a cohort of pregnant women in eastern Ethiopia.

Methods And Analysis: Vaginal and stool samples will be collected using DNA/RNA Shield Collection kits three times starting at 12-22 weeks, 28-36 weeks and at birth (within 7 days).

View Article and Find Full Text PDF

Aerosol dynamics in dental clinics: effects of ventilation mode on the mitigation of airborne diseases transmission.

Environ Pollut

January 2025

State Key Laboratory of Oral Diseases & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, Sichuan province, China. Electronic address:

Dental operations inherently involve a high risk of airborne cross-infection among medical staff and patients due to the exposure of respiratory secretions, which contain pathogenic microorganisms and typically spread in the form of aerosols. In order to contribute to the understanding of aerosol dynamics during dental operation and efficiently mitigate their dispersion and deposition through appropriate ventilation, 3D numerical simulations and full-scale experimental measurements were performed in this study. The indoor airflow distribution and dynamic aerosol behaviors observed under three optimized ventilation schemes (Scenario I-III) were compared with those observed under the current ventilation system.

View Article and Find Full Text PDF

The SARS-CoV-2 virus caused the COVID-19 pandemic and brought major challenges to public health. It is transmitted via aerosols, droplets, and fomites. Among these, viral transmission through fomites is not well understood although it remains a very important transmission route.

View Article and Find Full Text PDF

Indoor carbon monoxide exposures in a retail occupancy.

J Occup Environ Hyg

January 2025

R.E.M. Risk Consultants, Dallas, Texas.

In a two-story retail mall in the Southeastern United States, employees within Store A (located on the second level) began to feel headaches and general unease and discussed the symptoms among themselves. Approximately 1.5 hr later, an employee called 9-1-1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!