Background: Traditionally, tube feedings have been delayed after percutaneous endoscopic gastrostomy (PEG) placement to the next day and up to 24 h postprocedure. However, results from various randomized controlled trials (RCTs) indicate earlier feeding may be an option. We conducted a meta-analysis to analyze the effect of early feedings (< or = 4 h) after PEG placement.

Methods: Multiple databases were searched (November 2007). Only RCTs on adult subjects that compared early (< or = 4 h) versus delayed or next-day feedings after PEG placement were included. Meta-analyses for the effect of early and delayed feedings were analyzed by calculating pooled estimates of complications, death < or = 72 h, and significant increases in postprocedural gastric residual volume during day 1.

Results: Six studies (N = 467) met the inclusion criteria. No statistically significant differences were noted between early (< or = 4 h) and delayed or next-day feedings for patient complications (OR 0.86, 95% CI 0.47-1.58, P = 0.63) or death in < or = 72 h (OR 0.56, 95% CI 0.18-1.74, P = 0.31). A statistically significant increase in gastric residual volumes during day 1 was noted (OR 1.80, 95% CI 1.02-3.19, P = 0.04).

Conclusions: Early feeding < or = 4 h after PEG placement may represent a safe alternative to delayed or next-day feedings. Although an increase in significant gastric residual volumes at day 1 was noted, overall complications were not affected.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1572-0241.2008.02108.xDOI Listing

Publication Analysis

Top Keywords

peg placement
12
delayed next-day
12
next-day feedings
12
gastric residual
12
early versus
8
versus delayed
8
percutaneous endoscopic
8
endoscopic gastrostomy
8
feedings peg
8
early delayed
8

Similar Publications

Background: Tibial bone fractures in the malleolar regions are a major concern during the early postoperative period of total ankle replacement (TAR), affecting patient outcomes such as stability and recovery. Design, placement, and anatomic misalignment of implant components can contribute to malleolar fractures. The aim of this study is to understand the influence of implant design features, including keel, peg, stem, and bar type design, and bone-implant interfacial conditions on malleolar fracture following TAR.

View Article and Find Full Text PDF

Background: Despite the widespread use of percutaneous endoscopic gastrostomy (PEG) in pediatric populations, there is a paucity of data on the indications and outcomes of this procedure in Switzerland. This manuscript presents our experience with PEG indication, outcomes, and related complications in children.

Methods: This single-center retrospective study included patients < 18 years old who underwent PEG placement between 2007 and 2016.

View Article and Find Full Text PDF

Outcomes of percutaneous endoscopic gastrostomy (PEG) in HIV patients.

BMC Gastroenterol

December 2024

Division of Gastroenterology, Department of Medicine, BronxCare Health System, Clinical Affiliate of Mt Sinai Health Systems and Academic Affiliate of Icahn School of Medicine, 10C, 1650 Selwyn Avenue, Bronx, NY, 10457, USA.

Background: Percutaneous Endoscopic Gastrostomy (PEG) tube insertion, a routine procedure for long-term enteral nutrition, serves as a crucial intervention for patients who are incapable of tolerating oral intake or meeting adequate nutritional requirements. PEG tube placement carries complications like bleeding and infection. Impact of PEG tubes on the 30-day and long-term mortality in HIV patients is unknown.

View Article and Find Full Text PDF

Background: Tolerance of enteral nutrition following percutaneous endoscopic gastrostomy is a barrier to discharge. This study investigated the impact of an expedited feeding protocol following percutaneous endoscopic gastrostomy on postprocedure length of stay (LOS).

Methods: We performed a before-and-after cohort study on hospitalized adults in whom percutaneous endoscopic gastrostomy was placed by surgeons following the implementation of a standardized feeding protocol in which enteral feeds were resumed at the preoperative rate 6 h later.

View Article and Find Full Text PDF
Article Synopsis
  • Percutaneous endoscopic gastrostomy (PEG) placement is a routine procedure for patients needing non-oral feeding, but it can lead to rare complications like gastrocolocutaneous fistula, where the bowel is caught during placement.
  • A 73-year-old male on hospice experienced malodorous leakage from his PEG tube months after placement, prompting an emergency department visit where imaging revealed the tube was incorrectly positioned in the transverse colon.
  • The patient was treated non-surgically by removing the PEG tube and switching to a nasogastric tube for nutrition, highlighting the need for careful tube management and awareness of potential complications such as gastrocolocutaneous fistula in similar cases.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!