Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Trace element external quality assessment schemes monitor laboratory performance and provide a stimulus for improvement in accuracy. However, monitoring of participant performance varies according to the scheme and can lead to conflicting conclusions.
Methods: Quality specifications based on biological intra- and interindividual variability were calculated and compared to those currently used by various trace element external quality assessment schemes for plasma or serum copper, zinc, and selenium concentrations. For this purpose, we evaluated results reported by participating laboratories in different schemes, at key concentrations, using z scores.
Results: Minimal quality specifications developed from the biological intra- and interindividual variability were, for Cu, +/-0.84 micromol/L or 12% of the assigned target concentration, whichever is greater; for Zn, +/-1.20 micromol/L or 15% of the assigned target concentration, whichever is greater; and for Se, +/-0.072 micromol/L or 12% of the assigned target concentration, whichever is greater. Reported performance of the participating laboratories depended on analyte, concentration, and the selected quality specification. In addition, the most commonly used methods for the determination of Cu, Zn, and Se may give different results.
Conclusions: The proposed minimal quality specifications based on biological variation are generally slightly less stringent than those currently in use, although they do not drastically change the performance evaluation in the different schemes. These specifications are a first step in the harmonization of practices among the schemes and remain to be evaluated.