Objectives: This study evaluated the effect of thermal- and mechanical-cycling on the shear bond strength of three low-fusing glassy matrix dental ceramics to commercial pure titanium (cpTi) when compared to conventional feldspathic ceramic fused to gold alloy.

Methods: Metallic frameworks (diameter: 5 mm, thickness: 4 mm) (N=96, n=12 per group) were cast in cpTi and gold alloy, airborne particle abraded with 150 microm aluminum oxide. Low-fusing glassy matrix ceramics and a conventional feldspathic ceramic were fired onto the alloys (thickness: 4 mm). Four experimental groups were formed; Gr1 (control group): Vita Omega 900-Au-Pd alloy; Gr2: Triceram-cpTi; Gr3: Super Porcelain Ti-22-cpTi and G4: Vita Titankeramik-cpTi. While half of the specimens from each ceramic-metal combination were randomly tested without aging (water storage at 37 degrees C for 24 h only), the other half were first thermocycled (6000 cycles, between 5 and 55 degrees C, dwell time: 13 s) and then mechanically loaded (20,000 cycles under 50 N load, immersion in distilled water at 37 degrees C). The ceramic-alloy interfaces were loaded under shear in a universal test machine (crosshead speed: 0.5 mm/min) until failure occurred. Failure types were noted and the interfaces of the representative fractured specimens from each group were examined with stereomicroscope and scanning electron microscope (SEM). In an additional study (N=16, n=2 per group), energy dispersive X-ray spectroscopy (EDS) analysis was performed from ceramic-alloy interfaces. Data were analyzed using ANOVA and Tukey's test.

Results: Both ceramic-metal combinations (p<0.001) and aging conditions (p<0.001) significantly affected the mean bond strength values. Thermal- and mechanical-cycling decreased the bond strength (MPa) results significantly for Gr3 (33.4+/-4.2) and Gr4 (32.1+/-4.8) when compared to the non-aged groups (42.9+/-8.9, 42.4+/-5.2, respectively). Gr1 was not affected significantly from aging conditions (61.3+/-8.4 for control, 60.7+/-13.7 after aging) (p>0.05). Stereomicroscope images showed exclusively adhesive failure types at the opaque ceramic-cpTi interfacial zone with no presence of ceramic on the substrate surface but with a visible dark titanium oxide layer in Groups 2-4 except Gr1 where remnants of bonder ceramic was visible. EDS analysis from the interfacial zone for cpTi-ceramic groups showed predominantly 34.5-85.1% O(2) followed by 1.1-36.7% Al and 0-36.3% Si except for Super Porcelain Ti-22 where a small quantity of Ba (1.4-8.3%), S (0.7%) and Sn (35.3%) was found. In the Au-Pd alloy-ceramic interface, 56.4-69.9% O(2) followed by 15.6-26.2% Si, 3.9-10.9% K, 2.8-6% Na, 4.4-9.6% Al and 0-0.04% Mg was observed.

Significance: After thermal-cycling for 6000 times and mechanical-cycling for 20,000 times, Triceram-cpTi combination presented the least decrease among other ceramic-alloy combinations when compared to the mean bond strength results with Au-Pd alloy-Vita Omega 900 combination.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.dental.2008.07.002DOI Listing

Publication Analysis

Top Keywords

pure titanium
8
gold alloy
8
low-fusing glassy
8
glassy matrix
8
conventional feldspathic
8
feldspathic ceramic
8
ceramic-alloy interfaces
8
evaluation interface
4
interface characterization
4
characterization adhesion
4

Similar Publications

Clinical Efficacy of Three-Dimensional-Printed Pure Titanium Fracture Plates with Locking Screw Systems in Distal Tibia Fractures.

Medicina (Kaunas)

January 2025

Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.

Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.

View Article and Find Full Text PDF

Purpose: There are no universally established guidelines for material selection in orbital wall fracture reconstruction. With an increasing preference for permanent implants, this study aimed to compare the long-term clinical outcomes of three different non-resorbable materials in reconstructing isolated orbital floor fractures.

Design: A retrospective, interventional comparative study.

View Article and Find Full Text PDF

Biomagnetic fluid dynamics (BFD) is an emerging and promising field within fluid mechanics, focusing on the dynamics of bio-fluids like blood in the presence of magnetic fields. This research is crucial in the medical arena for applications such as medication delivery, diagnostic and therapeutic procedures, prevention of excessive bleeding, and treatment of malignant tumors using magnetic particles. This study delves into the intricacies of blood flow induced by cilia, carrying trihybrid nanoparticles (gold, copper, and titania), within a catheterized arterial annulus under a robust magnetic field.

View Article and Find Full Text PDF

Background: In some rare cases of congenital aplasia of the oval window (OW), malformed facial nerve (FN) locations covering the most or entire OW present a challenge to hearing reconstruction, there is no a highly effective surgical hearing reconstruction methods.

Aims/objectives: To update a Scala tympani drill-out technique (SDT) for abnormal FN course covering the OW.

Material And Methods: All patients of congenital atresia of the OW was recruited between August 2014 and July 2023 in a tertiary-care center.

View Article and Find Full Text PDF

As an exceptional 2D nanofiller, graphene oxide (GO) is extensively employed to amplify the protective properties of coatings. The dispersion of GO significantly influences the protective efficacy of the coatings. Here, a surface modification of GO through the integration of nanosized titanium dioxide (TiO) was employed, thereby facilitating the synthesis of an FGO-TiO nanoparticle characterized by a substantial interlayer spacing (0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!