Correlation optimized warping (COW) based on the total ion current (TIC) is a widely used time alignment algorithm (COW-TIC). This approach works successfully on chromatograms containing few compounds and having a well-defined TIC. In this paper, we have combined COW with a component detection algorithm (CODA) to align LC-MS chromatograms containing thousands of biological compounds with overlapping chromatographic peaks, a situation where COW-TIC often fails. CODA is a variable selection procedure that selects mass chromatograms with low noise and low background (so-called "high-quality" mass chromatograms). High-quality mass chromatograms selected in each COW segment ensure that the same compounds (based on their mass and their retention time) are used in the two-dimensional benefit function of COW to obtain correct and optimal alignments (COW-CODA). The performance of the COW-CODA algorithm was evaluated on three types of complex data sets obtained from the LC-MS analysis of samples commonly used for biomarker discovery and compared to COW-TIC using a new global comparison method based on overlapping peak area: trypsin-digested serum obtained from cervical cancer patients, trypsin-digested serum from a single patient that was treated with varying preanalytical parameters (factorial design study), and urine from pregnant and nonpregnant women. While COW-CODA did result in minor misalignments in rare cases, it was clearly superior to the COW-TIC algorithm, especially when applied to highly variable chromatograms (factorial design, urine). The presented algorithm thus enables automatic time alignment and accurate peak matching of multiple LC-MS data sets obtained from complex body fluids that are often used for biomarker discovery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac800920h | DOI Listing |
J Sep Sci
January 2025
College of Pharmacy, Anhui University of Chinese Medicine, Hefei, China.
Compound Shougong Powder (CSP) is a traditional Chinese medicine (TCM) preparation recognized for its efficacy in reducing swelling and relieving pain. It is primarily used clinically for the treatment of malignant tumors. However, research on the chemical compounds present in CSP remains limited.
View Article and Find Full Text PDFAnal Bioanal Chem
December 2024
Institute of Veterinary Medicine and Animal Sciences, Estonian University of Life Sciences, 51006, Tartu, Estonia.
The analysis of the volatile compounds released by biological samples represents a promising approach for the non-invasive diagnosis of a disease. The present study, focused on a population of dogs infected with canine leishmaniasis, aimed to decipher the volatolomic profile associated with this disease in dogs, which represent the main animal reservoir for Leishmania pathogen transmission to humans. The volatiles emitted by the breath and hair of dogs were analysed employing the gas chromatography-mass spectrometry (GC-MS) technique.
View Article and Find Full Text PDFEnviron Sci Process Impacts
December 2024
Department of Chemistry, University of Toronto, Canada.
Proton transfer reaction mass spectrometry (PTR-MS) is often employed to characterize gas-phase compounds in both indoor and outdoor environments. PTR-MS measurements are usually made without upstream chromatographic separation, so it can be challenging to differentiate between an ion of interest, its isomers, and fragmentation products from other species all detected at the same mass-to-charge ratio. These isomeric contributions and fragmentation interferences can confound the determination of accurate compound mixing ratios, the assignment of accurate chemical properties, and corresponding analyses of chemical fate.
View Article and Find Full Text PDFAnal Chem
December 2024
Laboratory of Chemical Biology, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven 5600 MB, The Netherlands.
Quantification of intact proteins in serum by liquid chromatography high-resolution mass spectrometry (HRMS) may be a useful alternative to bottom-up LC-MS or conventional ligand binding assays, due to reduced assay complexity and by providing additional information, such as isoform differentiation or detection of post-translational modifications. The 47.2 kDa lung cancer tumor marker neuron-specific enolase γ (NSEγ) was quantified in a clinically relevant concentration range of 6.
View Article and Find Full Text PDFBiol Trace Elem Res
December 2024
Institute of Microbiology and Molecular Genetics, University of the Punjab, Lahore, Pakistan.
This research explores the impact of arsenic exposure on serum protein profiles in type 2 diabetes patients, with an emphasis on the AS3MT protein as a biomarker. Utilizing Bradford protein assay, SDS-PAGE, HPLC, and mass spectrometry, we quantified and analyzed variations in serum protein levels, focusing on differences between control groups (82.94 ± 8.