Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Study Design: In vitro biomechanical investigation using human cadaveric vertebrae.
Objective: Evaluate the biomechanical differences in transverse plane vertebral body derotation maneuvers of thoracic pedicle screws in both medial and lateral directions.
Summary Of Background Data: Thoracic pedicle screws are thought to have better vertebral rotation control and better segmental scoliosis correction compared to hooks and wires. Little data exists regarding the biomechanical stability of pedicle screws when derotated in either medial or lateral directions.
Methods: Vertebral bodies (T4-L5) from 12 cadavers were instrumented with appropriate length pedicle screws while measuring insertion torque. Each body was anchored for independent loading in medial or lateral directions. Each screw was rotated around a rod using a constant length lever arm (30.5 cm) rigidly attached to the screw head simulating the posterior vertebral derotation maneuver. Yield torques (Nm) were analyzed using a one-way analysis of variance (P < 0.05).
Results: Yield torques for both directions were significantly related to screw insertion torque (both P < 0.01). There were no statistical differences in yield torque between medial (12.0 +/- 4.9 Nm) or lateral (11.5 +/- 5.1 Nm) directions. There were no significant differences after normalization for insertion torque or screw length. Tests rotating the screw tip laterally demonstrated structural failure in the following percentages (anterolateral failure = 67%, posterior element failure = 33%, additional screw bending = 42%). Rotation medially demonstrated structural failures in the following percentages (canal penetration = 51%, posterior element failure = 49%, additional screw bending = 44%).
Conclusion: From these data, a surgeon performing a direct vertebral derotation using a 30 cm (12 in) lever would need to apply roughly 40 N (9 lbs) to causeanatomic failure. Adolescent patients would likely tolerate a greater force without bone failure given a greater bone density, yet, extreme caution is still recommended to prevent screw rotation either medially into the spinal canal or laterally into the chest.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BRS.0b013e31817f12a9 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!