During an intravascular ultrasound (IVUS) intervention, a catheter with an ultrasound transducer is introduced in the body through a blood vessel, and then, pulled back to image a sequence of vessel cross sections. Unfortunately, there is no 3-D information about the position and orientation of these cross-section planes, which makes them less informative. To position the IVUS images in space, some researchers have proposed complex stereoscopic procedures relying on biplane angiography to get two X-ray image sequences of the IVUS transducer trajectory along the catheter. To simplify this procedure, we and others have elaborated algorithms to recover the transducer 3-D trajectory with only a single view X-ray image sequence. In this paper, we present an improved method that provides both automated 2-D and 3-D transducer tracking based on pullback speed as a priori information. The proposed algorithm is robust to erratic pullback speed and is more accurate than the previous single-plane 3-D tracking methods.

Download full-text PDF

Source
http://dx.doi.org/10.1109/titb.2008.921043DOI Listing

Publication Analysis

Top Keywords

ivus transducer
8
transducer tracking
8
image sequence
8
x-ray image
8
pullback speed
8
transducer
5
robust 3-d
4
ivus
4
3-d ivus
4
tracking single-plane
4

Similar Publications

Multimodal intravascular ultrasound and photoacoustic (IVUS/PA) imaging is a promising diagnostic tool for cardiovascular diseases like atherosclerosis. IVUS/PA catheters typically require two independent transducers due to different frequency requirements, potentially increasing the catheter size. To facilitate multimodal imaging within conventional catheter dimensions, we designed, fabricated, and characterized a dual-transducer acoustic stack where a low-frequency (LF) PA receiver sits as a matching layer for the high-frequency (HF) US transducer.

View Article and Find Full Text PDF

Sm-doped Pb(MgNb)O-0.28PbTiO (PMN-0.28PT) ceramic has been reported to exhibit very large piezoelectric response (~1300 pC/N) that can be comparable with PMN-0.

View Article and Find Full Text PDF
Article Synopsis
  • * A 74-year-old male with CTO in his right external iliac artery was successfully treated using the I-PAD method, which combines intravascular ultrasound (IVUS) and an angled guiding catheter.
  • * The procedure was completed quickly, without complications, suggesting that the I-PAD technique could improve the efficiency and safety of treating CTO lesions.
View Article and Find Full Text PDF

Coronary artery disease (CAD) is one of the leading causes of death globally. Currently, diagnosis and intervention in CAD are typically performed via minimally invasive cardiac catheterization procedures. Using current diagnostic technology, such as angiography and fractional flow reserve (FFR), interventional cardiologists must decide which patients require intervention and which can be deferred; 10% of patients with stable CAD are incorrectly deferred using current diagnostic best practices.

View Article and Find Full Text PDF

Intravascular ultrasound (IVUS) imaging catheters are significant tools for cardiovascular interventions, and their use can be expanded by realizing IVUS imaging guidewires and microcatheters. The miniaturization of these devices creates challenges in SNR due to the need for higher frequencies to provide adequate resolution. An integrated IVUS system with transmit beamforming can mitigate these limitations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!