Objective: The objective was to compare the medium- and long-term outcomes for pericardial monocusp valves, polytetrafluoroethylene (Gore-Tex, WL Gore and Associates Inc, Flagstaff, Ariz) 0.1-mm monocusp valves, and bileaflet 0.l-mm polytetrafluoroethylene valves and their efficiency in the right ventricular outlet.

Methods: We reviewed all hand-sewn right ventricular outlet valves created by the author (Graham R. Nunn) in the setting of repaired tetralogy of Fallot or equivalent right ventricular outlet pathology when the native pulmonary valve could not be preserved. The valves were assessed by serial transthoracic echocardiography and more recently by magnetic resonance imaging angiography for late valve function. The bileaflet polytetrafluoroethylene valves were constructed in a standardized fashion from a semicircle of 0.1-mm polytetrafluoroethylene (the radius of which equaled the length of the outflow tract incision) that gave a lengthened free edge to the leaflets, central fixation of the free edge posteriorly just proximal to the branch pulmonary arteries, and generous augmentation of the outflow tract with polytetrafluoroethylene patch-plasty. The bileaflet configuration shortens the closing time against the posterior wall, and the leaflets are forced to maintain their configuration without prolapse into the right ventricular outlet. The valve can be generously oversized in young children to try to avoid the need for replacement.

Results: A total of 54 patients met the selection criteria--22 patients received fresh autologous pericardial monocusps, 7 patients received polytetrafluoroethylene (0.1-mm) monocusps, and 25 patients received bileaflet polytetrafluoroethylene (0.1-mm) outlet valves. The pericardial valves have the longest follow-up, and all valves developed free pulmonary incompetence. Polytetrafluoroethylene monocusps had reliable competence early after surgery but progressed to pulmonary incompetence. The bileaflet polytetrafluoroethylene (0.1-mm) valves have remained competent with regurgitant fractions of only 5% to 30% (magnetic resonance imaging angiography), and this has remained stable with time. The maximum follow-up for these valves is 5 years. No stenosis or peripheral emboli have been recognized, and no valves have been replaced to date.

Conclusion: Hand-sewn bileaflet polytetrafluoroethylene valves in the right ventricular outlet can reliably provide competence and maintain function in the medium term. Their shape and size allow placement in young children with a reasonable expectation that they will remain competent with growth of the native annulus and not require replacement. Their durability is superior to the pericardial and polytetrafluoroethylene monocusp valves in this series.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2008.02.063DOI Listing

Publication Analysis

Top Keywords

ventricular outlet
20
bileaflet polytetrafluoroethylene
16
valves
15
monocusp valves
12
polytetrafluoroethylene valves
12
patients received
12
polytetrafluoroethylene 01-mm
12
polytetrafluoroethylene
11
valves ventricular
8
outlet valves
8

Similar Publications

Double outlet right ventricle (DORV) is a rare congenital heart defect where both the aorta and pulmonary artery originate from the right ventricle, often accompanied by additional cardiac anomalies to mitigate circulatory imbalance, though such compensations usually fail. We report a 15-month-old infant with recurrent respiratory infections and poor weight gain, referred for computed tomography angiography. Physical examination showed a small, non-syndromic infant with pallor, tachypnea, irritability, and finger clubbing.

View Article and Find Full Text PDF

Prenatal Predictors and Early Postnatal Outcomes in Fetuses Diagnosed with Tricuspid Atresia.

Diagnostics (Basel)

December 2024

Zeynep Kamil Women and Children's Diseases Training and Research Hospital, Department of Perinatology, Health Science University, Istanbul 34668, Turkey.

To assess the prenatal course and early postnatal outcomes of fetuses diagnosed with tricuspid atresia and to identify predictors of survival. This was a retrospective study of 25 fetuses diagnosed with tricuspid atresia in a single tertiary referral center, evaluating prenatal echocardiographic features and postnatal outcomes. A total of 4 of 29 initially diagnosed fetuses were excluded due to changes in diagnosis or loss to follow-up, leaving 25 fetuses for analysis.

View Article and Find Full Text PDF

We sought to evaluate the intracardiac morphology and associated cardiovascular anomalies in patients with double inlet right ventricle (DIRV) on multidetector CT angiography. A retrospective search of our departmental database was conducted from January 2014 to January 2023 to identify patients with a diagnosis of DIRV on CT angiography. The intracardiac anatomy and associated cardiovascular abnormalities were systematically evaluated.

View Article and Find Full Text PDF

Background: Perimembranous ventricular septal defect (VSD) can be classified as having trabecular, inlet, or outlet extension. The surgical approach used in patch closure depends on the which valve of the tricuspid valve to suture around and the avoidance of the specialized conducting system. This retrospective study evaluated the usefulness of the "En face view" method for classifying perimembranous VSD.

View Article and Find Full Text PDF

Background: Infective endocarditis (IE) poses significant risks following percutaneous pulmonary valve implantation (PPVI) or surgical replacement (PVR).

Aims: This study evaluates the effectiveness of emergency percutaneous treatment in stabilizing patients with severe right ventricular dysfunction or obstructive cardiac shock, allowing for delayed surgical or percutaneous valve replacement.

Methods: This retrospective study examines 16 patients (age 19.

View Article and Find Full Text PDF