A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Iron oxide nanoparticles-chitosan composite based glucose biosensor. | LitMetric

Iron oxide nanoparticles-chitosan composite based glucose biosensor.

Biosens Bioelectron

Biomolecular Electronics & Conducting Polymer Research Group, National Physical Laboratory, K.S. Krishnan Marg, New Delhi 110012, India.

Published: December 2008

Iron oxide (Fe(3)O(4)) nanoparticles prepared using co-precipitation method have been dispersed in chitosan (CH) solution to fabricate nanocomposite film on indium-tin oxide (ITO) glass plate. Glucose oxidase (GOx) has been immobilized onto this CH-Fe(3)O(4) nanocomposite film via physical adsorption. The size of the Fe(3)O(4) nanoparticles estimated using X-ray diffraction (XRD) pattern and transmission electron microscopy (TEM) has been found to be approximately 22 nm. The CH-Fe(3)O(4) nanocomposite film and GOx/CH-Fe(3)O(4)/ITO bioelectrode have been characterized using UV-visible and Fourier transform infrared (FTIR) spectroscopic and scanning electron microscopy (SEM) techniques, respectively. This GOx/CH-Fe(3)O(4)/ITO nanocomposite bioelectrode has response time of 5s, linearity as 10-400 mgdL(-1) of glucose, sensitivity as 9.3 microA/(mgdLcm(2)) and shelf life of about 8 weeks under refrigerated conditions. The value of Michaelis-Menten (K(m)) constant obtained as 0.141 mM indicates high affinity of immobilized GOx towards the substrate (glucose).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2008.06.032DOI Listing

Publication Analysis

Top Keywords

nanocomposite film
12
iron oxide
8
fe3o4 nanoparticles
8
ch-fe3o4 nanocomposite
8
electron microscopy
8
oxide nanoparticles-chitosan
4
nanoparticles-chitosan composite
4
composite based
4
glucose
4
based glucose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!