A case of percutaneous pulmonary valve implantation following a failed homograft in the pulmonary position is reported. A 16-year-old boy developed infective endocarditis of his pulmonary homograft, which was implanted four years earlier during a Ross procedure for congenital aortic stenosis. Following successful medical therapy, the boy was symptomatic due to pulmonary stenosis and regurgitation. A 22 mm Melody valve (Medtronic, USA) was successfully implanted percutaneously. His symptoms resolved and he was discharged home one day after the procedure. Echocardiography at the six-month follow-up demonstrated a normally functioning pulmonary valve. Percutaneous pulmonary valve replacement may make the Ross procedure a more attractive option for patients with aortic stenosis, particularly in the pediatric population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2644368 | PMC |
http://dx.doi.org/10.1016/s0828-282x(08)70656-1 | DOI Listing |