Ion soft landing using a rectilinear ion trap mass spectrometer.

Anal Chem

Department of Chemistry, 560 Oval Drive, Purdue University, West Lafayette, Indiana 47907, USA.

Published: September 2008

A new ion soft landing instrument has been built for the controlled deposition of mass selected polyatomic ions. The instrument has been operated with an electrospray ionization source; its major components are an electrodynamic ion funnel to reduce ion loss, a 90-degree bent square quadrupole that prevents deposition of fast neutral molecules onto the landing surface, and a novel rectilinear ion trap (RIT) mass analyzer. The ion trap is elongated (inner dimensions: 8 mm x 10 mm x 10 cm). Three methods of mass analysis have been implemented. (i) A conventional mass-selective instability scan with radial resonance ejection can provide a complete mass spectrum. (ii) The RIT can also be operated as a continuous rf/dc mass filter for isolation and subsequent soft landing of ions of the desired m/ z value. (iii) The 90-degree bent square quadrupole can also be used as a continuous rf/dc mass filter. The mass resolution (50% definition) of the RIT in the trapping mode (radial ion ejection) is approximately 550. Ions from various test mixtures have been mass selected and collected on fluorinated self-assembled monolayers on gold substrates, as verified by analysis of the surface rinses. Desorption electrospray ionization (DESI) has been used to confirm intact deposition of [Val (5)]-Angiotensin I on a surface. Nonmass selective currents up to 1.1 nA and mass-selected currents of up to 500 pA have been collected at the landing surface using continuous rf/dc filtering with the RIT. A quantitative analysis of rinsed surfaces showed that the overall solution-to-solution soft landing yields are between 0.2 and 0.4%. Similar experiments were performed with rf/dc isolation of both arginine and lysine from a mixture using the bent square quadrupole in the rf/dc mode. The unconventional continuous mass selection methods maximize soft landing yields, while still allowing the simple acquisition of full mass spectra.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac800929wDOI Listing

Publication Analysis

Top Keywords

soft landing
20
ion trap
12
bent square
12
square quadrupole
12
continuous rf/dc
12
mass
11
ion
8
ion soft
8
rectilinear ion
8
mass selected
8

Similar Publications

Modeling and analysis of explicit dynamics of foot landing.

Med Biol Eng Comput

January 2025

School of Medical Engineering, Department of Cardiology of The First Affiliated Hospital of Xinxiang Medical University, Xinxiang Medical University, Xinxiang, 453003, Henan, China.

The research aims to investigate the mechanical response of footfalls at different velocities to understand the mechanism of heel injury and provide a scientific basis for the prevention and treatment of heel fractures. A three-dimensional solid model of foot drop was constructed using anatomical structures segmented from medical CT scans, including bone, cartilage, ligaments, plantar fascia, and soft tissues, and the impact velocities of the foot were set to be 2 m/s, 4 m/s, 6 m/s, 8 m/s, and 10 m/s. Explicit kinetic analysis methods were used to investigate the mechanical response of the foot landing with different speeds to explore the damage mechanism of heel bone at different impact velocities.

View Article and Find Full Text PDF

An ion soft-landing apparatus for ion transport study with surface potential measurement.

Rev Sci Instrum

October 2024

BNLMS, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China.

Article Synopsis
  • - An apparatus has been developed to investigate ion transport in materials and at interfaces, utilizing an ion soft-landing technique that deposits low-energy ions onto a medium layer on a metal surface.
  • - The apparatus features a mass-filtered ion source that can deliver a very low kinetic energy ion beam (under 1.0 eV) from bulk metals and salts, allowing for gentle ion deposition.
  • - Using a highly sensitive Kelvin probe to measure surface potential changes, initial experiments on Ag+-adsorbed ice films indicate significant ion transport behavior starting at around 110 K, showcasing the system's effectiveness for detailed ion transport studies.
View Article and Find Full Text PDF

Combustion visualization analysis of alternative fuels in the pulverized coal injection raceway through laminar flow reactor.

Heliyon

September 2024

School of Mechanical Engineering, Pusan Nat'l Univ., 2, Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan, 46241, Republic of Korea.

Currently, the steelmaking process uses a pulverized coal injection (PCI) system that serves as the heat source and reductant for ironmaking (blast furnace and FINEX) where system uses expensive high-grade coal and high operating costs. Hydrogen steelmaking is currently being developed to achieve carbon-free operation. To achieve a soft-landing during this phase of rapid change, the use of biomass and inexpensive, thermal coal, and coke dust is necessary.

View Article and Find Full Text PDF

Influence of Polytetrafluoroethylene Content, Compaction Pressure, and Annealing Treatment on the Magnetic Properties of Iron-Based Soft Magnetic Composites.

Molecules

August 2024

Key Laboratory of High Density Electromagnetic Power and Systems (Chinese Academy of Sciences), Institute of Electrical Engineering, Chinese Academy of Sciences, Haidian District, Beijing 100190, China.

To improve the magnetic properties of iron-based soft magnetic composites (SMCs), polytetrafluoroethylene (PTFE) with excellent heat resistance, electrical insulation, and extremely high electrical resistivity was chosen as an insulating coating material for the preparation of iron-based SMCs. The effects of PTFE content, compaction pressure, and annealing treatment on the magnetic properties of Fe/PTFE SMCs were investigated in detail. The results demonstrate that the PTFE insulating layer is successfully coated on the surface of iron powders, which effectively reduces the core loss, increases the resistivity, and improves the frequency stability and the quality factor.

View Article and Find Full Text PDF

Writing with Mass-Selected Ions Using a Dynamic Field Wien Filter.

J Am Soc Mass Spectrom

October 2024

James Tarpo Jr. and Margaret Tarpo Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States.

We have designed and constructed a low-cost Wien filter based on strong permanent magnets and integrated it into an ion soft-landing instrument to enable parallel deposition as well as one- and two-dimensional surface patterning of mass-selected ions using dynamic fields. We show the capabilities of this device for separating ions from a multicomponent high-flux continuous ion beam and simultaneous deposition of ions of different mass-to-charge ratios onto discrete locations on a surface. When a dynamic electric field is applied parallel to the magnetic field, ions are deposited in one-dimensional arrays, laterally separated by mass.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!