A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The role of pulse duration and stimulation duration in maximizing the normalized torque during neuromuscular electrical stimulation. | LitMetric

The role of pulse duration and stimulation duration in maximizing the normalized torque during neuromuscular electrical stimulation.

J Orthop Sports Phys Ther

Department of Physical Therapy, Indiana University, Indianapolis, IN 46202-5119, USA.

Published: August 2008

Study Design: Controlled laboratory study

Objectives: To determine the effects of pulse duration and stimulation duration on the evoked torque after controlling for the activated area by using magnetic resonance imaging (MRI).

Background: Neuromuscular electrical stimulation (NMES) is commonly used in the clinic without considering the physiological implications of its parameters.

Methods And Measures: Seven able-bodied, college students (mean +/- SD age, 28 +/- 4 years) participated in this study. Two NMES protocols were applied to the knee extensor muscle group in a random order. Protocol A applied 100-Hz, 450-microsecond pulses for 5 minutes in a 3-seconds-on 3-seconds-off duty cycle. Protocol B applied 60-Hz, 250-microsecond pulses for 5 minutes in a 10-seconds-on 20-seconds-off duty cycle. The amplitude of the current was similar in both protocols. Torque, torque time integral, and normalized torque for the knee extensors were measured for both protocols. MRI scans were taken prior to, and immediately after, each protocol to measure the cross-sectional area of the stimulated muscle.

Results: The skeletal muscle cross-sectional areas activated after both protocols were similar. The longer pulse duration in protocol A elicited 22% greater torque output than that of protocol B (P<.05). After considering the activated area in both protocols, the normalized torque with protocol A was 38% greater than that with protocol B (P<.05). Torque time integral was 21% greater with protocol A (P = .029). Protocol B failed to maintain torque at the start and the end of the 10-second activation.

Conclusions: Longer pulse duration, but not stimulation duration, resulted in a greater evoked and normalized torque compared to the shorter pulse duration, even after controlling for the activated muscular cross-sectional areas with both protocols.

Level Of Evidence: Therapy, level 5.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2554670PMC
http://dx.doi.org/10.2519/jospt.2008.2734DOI Listing

Publication Analysis

Top Keywords

pulse duration
12
duration stimulation
8
stimulation duration
8
normalized torque
8
neuromuscular electrical
8
electrical stimulation
8
protocol applied
8
pulses minutes
8
duty cycle
8
torque
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!