Rationale And Objectives: To evaluate whether dynamic computed tomography (CT)-imaging can provide functional vessel information in patients with chronic aortic dissection type Stanford-B (ADB).

Materials And Methods: In 32 patients, ECG-gated CT-angiography images were obtained. Cross-sectional area change and wall distensibility were investigated by semiautomatic vessel area segmentation at the end of aortic arch. Significance of distensibility differences was tested with regard to the aortic diameter, and the oscillation of the intimal flap was analyzed.

Results: The aorta could be segmented successfully in all patients. These were separated into three subgroups: (A) 6 patients with an aortic diameter <4 cm and without a visible intimal flap, (B) 9 patients with an aortic diameter <4 cm, and (C) 17 individuals with an aortic diameter > or = 4 cm; (B) and (C) having a visible intimal flap. Differences in distensibility between the subgroups were not significant. Overall mean distensibility was D(tot)=(1.3+/-0.6) x 10(-5) Pa(-1). Analysis of intimal flap oscillation showed a pulsatile short axis diameter decrease of the true lumen of up to 29%.

Conclusion: Dynamic, ECG-gated CT-angiography can demonstrate pulsatile changes in aortic area and a highly variable motion of the intimal flap. Aortic distensibility appears independent of diameter or presence of a intimal flap. Follow-up studies may show correlation with possible complications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2008.06.024DOI Listing

Publication Analysis

Top Keywords

intimal flap
8
patients chronic
8
aortic diameter
8
aortic
5
patients
5
motion characterization
4
characterization aortic
4
aortic wall
4
wall intimal
4
flap ecg-gated
4

Similar Publications

Acute ischemic stroke, a medical emergency caused by reduced cerebral blood flow, results in brain cell damage. While commonly associated with older individuals, strokes can also occur in young and middle-aged adults, posing significant socio-economic and health challenges due to the long-term impact of the condition. This poses significant socio-economic and health challenges because stroke is a leading cause of disability and mortality.

View Article and Find Full Text PDF

4D computed tomography assessment of ruptured triple-lumen type B aortic dissection: a case report.

Eur Heart J Case Rep

December 2024

Department of Cardiac Surgery, The Second Affiliated Hospital, Army Medical University (Third Military Medical University), Chongqing 400030, China.

Background: Few studies have investigated the effect of the intimal morphology of type B aortic dissection (TBAD) on the blood flow after rupture. We report a case of a 30-year-old male with complicated TBAD, who underwent assessment with 4D computed tomography (4D-CT).

Case Summary: Patient presented with chest tightness for 14 days, a heart rate of 67 b.

View Article and Find Full Text PDF
Article Synopsis
  • *Transesophageal echocardiography (TEE) is the primary diagnostic method for IAD, but its accuracy can be compromised by artifacts that lead to misinterpretation.
  • *In a case involving a 55-year-old man undergoing surgery, TEE suggested IAD based on the presence of an intimal dissection flap, but this was not confirmed by computed tomographic angiography, highlighting the diagnostic challenges in complex surgical situations.
View Article and Find Full Text PDF

A male neonate (2.5 kg) who presented with an interrupted aortic arch type C, hypoplasia of the aortic valve and left ventricular outflow tract obstruction received bilateral pulmonary artery bands as a first step of a hybrid interim palliation. Due to an intimal tissue flap at the origin of the left common carotid artery and a high-risk situation for PDA stenting, a complete early correction was undertaken.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!