A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Membrane coagulation bioreactor (MCBR) for drinking water treatment. | LitMetric

Membrane coagulation bioreactor (MCBR) for drinking water treatment.

Water Res

School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China.

Published: August 2008

In this paper, a novel submerged ultrafiltration (UF) membrane coagulation bioreactor (MCBR) process was evaluated for drinking water treatment at a hydraulic retention time (HRT) as short as 0.5h. The MCBR performed well not only in the elimination of particulates and microorganisms, but also in almost complete nitrification and phosphate removal. As compared to membrane bioreactor (MBR), MCBR achieved much higher removal efficiencies of organic matter in terms of total organic carbon (TOC), permanganate index (COD(Mn)), dissolved organic carbon (DOC) and UV absorbance at 254nm (UV(254)), as well as corresponding trihalomethanes formation potential (THMFP) and haloacetic acids formation potential (HAAFP), due to polyaluminium chloride (PACl) coagulation in the bioreactor. However, the reduction of biodegradable dissolved organic carbon (BDOC) and assimilable organic carbon (AOC) by MCBR was only 8.2% and 10.1% higher than that by MBR, indicating that biodegradable organic matter (BOM) was mainly removed through biodegradation. On the other hand, the trans-membrane pressure (TMP) of MCBR developed much lower than that of MBR, which implies that coagulation in the bioreactor could mitigate membrane fouling. It was also identified that the removal of organic matter was accomplished through the combination of three unit effects: rejection by UF, biodegradation by microorganism and coagulation by PACl. During filtration operation, a fouling layer was formed on the membranes surface of both MCBR and MBR, which functioned as a second membrane for further separating organic matter.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2008.05.025DOI Listing

Publication Analysis

Top Keywords

coagulation bioreactor
16
organic matter
16
organic carbon
16
membrane coagulation
8
bioreactor mcbr
8
drinking water
8
water treatment
8
organic
8
dissolved organic
8
formation potential
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!