Purpose: To examine the ability of TrueFISP imaging for evaluating tumor size in mouse brain at high field.

Materials And Methods: Brains of healthy and glioma-implanted nude mice were imaged at 4.7T and 9.4T. 3D imaging was performed with TrueFISP and T2w-RARE. Radiofrequency pulses with alternating phase and the sum-of-squares reconstruction method were used in TrueFISP imaging. The contrast-to-noise ratio (CNR) was evaluated in healthy and in tumoral brain regions.

Results: Banding artifact was correctly suppressed in TrueFISP images thanks to the method used. The signal-to-noise ratio (SNR) and CNR were comparable in TrueFISP and T2w-RARE images at 4.7T, but acquisition was around 4 times shorter with TrueFISP. Tumor was well detected at 4.7T with TrueFISP, but CNR between tumor and healthy tissue was low at 9.4T.

Conclusion: TrueFISP is efficient and fast to perform brain imaging at 4.7T. Multiple TrueFISP acquisitions with phase-cycled radiofrequency (RF) pulses and sum-of-squares reconstruction allow suppression of banding artifact. Tumoral regions were well detected and the method allows longitudinal studies of tumor growth.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jmri.21449DOI Listing

Publication Analysis

Top Keywords

truefisp imaging
12
truefisp
10
mouse brain
8
47t 94t
8
truefisp t2w-rare
8
radiofrequency pulses
8
sum-of-squares reconstruction
8
banding artifact
8
well detected
8
47t
5

Similar Publications

Objective: The objective of this study was to identify sex differences in ntrahepatocellular (HCL) and intramyocardial lipids (MYCL) and cardiac function in participants with different grades of glucometabolic impairment and different BMI strata.

Methods: Data from 503 individuals from 17 clinical experimental studies were analyzed. HCL and MYCL were assessed with 3T and 7T scanners by magnetic resonance spectroscopy.

View Article and Find Full Text PDF

Three-dimensional gradient-echo (3D-GRE) sequences provide isotropic or nearly isotropic 3D images, leading to better visualization of smaller structures, compared to two-dimensional (2D) sequences. The aim of this study was to prospectively compare 2D and 3D-GRE sequences in terms of key imaging metrics, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), glenohumeral joint space, image quality, artifacts, and acquisition time in shoulder joint images, using 1.5-T MRI scanner.

View Article and Find Full Text PDF

Objective: Aortic Dissection (AD) is one of the most fatal acute diseases in cardiovascular diseases, with rapid onset and progression and a high fatality rate. This study aims to investigate the clinical values of non-enhancement peripheral pulse-gating rapid magnetic resonance imaging in deterministic diagnosis of AD.

Methods: Aorta magnetic resonance imaging was performed in 21 healthy volunteers at a 1.

View Article and Find Full Text PDF

Radiomics of cardiac magnetic resonance (MR) imaging has proved to be potentially useful in the study of various myocardial diseases. Therefore, assessing the repeatability degree in radiomic features measurement is of fundamental importance. The aim of this study was to assess test-retest repeatability of myocardial radiomic features extracted from quantitative T1 and T2 maps.

View Article and Find Full Text PDF

Background: Cytomegalovirus (CMV) is the most common intrauterine infection and may be associated with unfavorable outcomes. While some CMV-infected fetuses may show gross or subtle brain abnormalities on MRI, their clinical significance may be unclear. Conversely, normal development cannot be guaranteed in CMV-infected fetuses with normal MRI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!