Multiple-detector computed tomographic angiography of pancreatic neoplasm for presurgical planning: comparison of low- and high-concentration nonionic contrast media.

J Comput Assist Tomogr

Abdominal Imaging and Interventional Radiology, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA.

Published: August 2008

Objective: To evaluate the degree of contrast enhancement, image quality, and accuracy of predicting resectability of pancreatic neoplasm with 16-row multiple-detector computed tomography (MDCT) angiography using low- and high-concentration (300 and 370 mg of iodine per milliliter, respectively) contrast media (CMs).

Materials And Methods: Forty patients who had undergone pancreatic CT angiography (CTA) on 16-MDCT scanner and had surgery were included. Contrast medium of 2 iodine concentrations (group A, 300 mg/mL, n = 20; group B, 370 mg/mL, n = 20) from the same vendor (Isovue; Bracco Diagnostics), with iodine dose of 550 to 600 mg/kg of body weight, was injected at a rate of 5 mL/s. Dual-phase 16-row MDCT was performed using 1.25- and 5-mm collimation for the arterial and portal phases, respectively. For the quantitative analysis, Hounsfield units values in the aorta, superior mesenteric artery, portal vein, and pancreas during arterial and venous phases were measured. Two readers subjectively rated the overall image enhancement, 3-dimensional image quality, and lesion and pancreatic duct conspicuity. Accuracy of lesion resectability was also established for each patient. The data were compared using Student t test for statistical analysis.

Results: The quantitative analysis for the degree of enhancement (Hounsfield unit) of the aorta, superior mesenteric artery, and pancreas during the arterial phase demonstrated similar values in groups A (low-concentration CM) and B (high-concentration CM), with no statistically significant difference with each other (P > 0.05). During the portal venous phase, we found superior enhancements in the superior mesenteric and portal veins in group A (P < 0.05). The qualitative assessments of the overall image enhancement and 3-dimensional image quality on a 5-point scale were 4.3 and 4.65, respectively (P < 0.05), in group A and 4.6 and 4.75, respectively, in group B, whereas on a 3-point scale, the pancreatic duct display and lesion conspicuity were 2.75 and 2.85, respectively, in group A and 2.9 and 2.9, respectively, in group B. The accuracy for lesion resectability was 95% (19/20) in group A and 100% (20/20) in group B (P > 0.05).

Conclusion: Both CMs demonstrated comparable performance for 16-row MDCT of the pancreas for presurgical planning. However, high-concentration CM (370 mg of iodine per milliliter) provides higher overall enhancement and superior-quality 3-dimensional images with a shorter injection duration.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RCT.0b013e31813ffd12DOI Listing

Publication Analysis

Top Keywords

image quality
12
superior mesenteric
12
group
9
multiple-detector computed
8
pancreatic neoplasm
8
presurgical planning
8
low- high-concentration
8
contrast media
8
370 iodine
8
iodine milliliter
8

Similar Publications

The evolution of radiation therapy in Uganda has been a journey marked by significant milestones and persistent challenges. Since the inception of radiotherapy services in 1988-1989, there has been a concerted effort to enhance cancer treatment services. The early years were characterized by foundational developments, such as the installation of the first teletherapy units, low-dose-rate brachytherapy units, and conventional simulators, and the recognition of radiation oncologists and medical physicist professionals laid the groundwork for radiotherapy treatment modalities.

View Article and Find Full Text PDF

Survivors of pediatric brain tumours are at a high risk of cognitive morbidity. Reliable individual-level predictions regarding the likelihood, degree, and affected domains of cognitive impairment would be clinically beneficial. While established risk factors exist, quantitative MRI analysis may enhance predictive value, above and beyond current clinical risk models.

View Article and Find Full Text PDF

Obtaining high-quality matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) images and the reproducibility of the technique depend strongly on the sample preparation protocol. The most crucial part is the application of the MALDI matrix, which often relies on expensive spraying or sublimation coaters. In this work, we present a new dual-polarity matrix for MALDI mass spectrometry imaging (MSI): Basic Blue 7 (BB7), which belongs to the group of triarylmethane dyes.

View Article and Find Full Text PDF

Bone Health and Linear Growth in Children with Familial Hypoparathyroidism Treated with Human Parathyroid Hormone 1-34.

J Clin Endocrinol Metab

January 2025

Gastroenterology, Hepatology and Nutrition, Cincinnati Childrens Hospital Medical Center, Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH.

Context: Our study explores the impact of human PTH 1-34 injections (PTH therapy) on growth, areal bone mineral density (BMD), and bone quality (measured by trabecular bone score, TBS) in hypoparathyroidism due to autoimmune polyendocrine syndrome type 1 (APS-1) or an activating variant of the calcium sensing receptor (CaR).

Objective: To assess associations of 1) age and PTH therapy duration with age-standardized Z-scores for height (HAZ), BMD (BMD-Z), and TBS (TBS-Z) in CaR or APS-1, and 2) APS-1 disease severity with BMD-Z and TBS-Z.

Methods: This secondary analysis pooled linear growth and lumbar spine (LS) DXA data from studies of hypoparathyroidism with mean baseline age of 13.

View Article and Find Full Text PDF

A review of state-of-the-art resolution improvement techniques in SPECT imaging.

EJNMMI Phys

January 2025

Department of Nuclear Medicine, Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, 230001, Anhui, China.

Single photon emission computed tomography (SPECT), a technique capable of capturing functional and molecular information, has been widely adopted in theranostics applications across various fields, including cardiology, neurology, and oncology. The spatial resolution of SPECT imaging is relatively poor, which poses a significant limitation, especially the visualization of small lesions. The main factors affecting the limited spatial resolution of SPECT include projection sampling techniques, hardware and software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!