A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of rapid coagulase serotyping method by PCR and microplate hybridization. | LitMetric

Development of rapid coagulase serotyping method by PCR and microplate hybridization.

J Microbiol Methods

Fukuyama City Public Health Center, 2-11-22, Miyoshi-chou-minami, Fukuyama, Hiroshima 720-0032, Japan.

Published: October 2008

We developed a novel PCR-based method for coagulase serotyping. Coagulase gene amplicons biotinylated by PCR were identified by microplate hybridization (MPH) using serotype-specific probes. The conventional serotyping method, which is strongly dependent on coagulase activity, may sometimes give a mistaken determination of the serotype, especially in cases where there is high coagulase activity. In contrast, the results of PCR-MPH are not affected by coagulase activity. Furthermore, once the isolated colonies are obtained, it only takes 3 h to perform PCR-MPH, and the interpretation of the results is entirely objective. We compared PCR-MPH with the conventional method for 90 strains of coagulase-producing Staphylococcus aureus. The same results were found for both the PCR-MPH and conventional methods, and thus, our results indicate that PCR-MPH is a rapid, objective, and reliable method for coagulase serotyping.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mimet.2008.07.001DOI Listing

Publication Analysis

Top Keywords

coagulase serotyping
12
coagulase activity
12
serotyping method
8
microplate hybridization
8
method coagulase
8
pcr-mph conventional
8
coagulase
7
method
5
pcr-mph
5
development rapid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!