A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of outcomes of peritoneal dialysis catheters placed by the fluoroscopically guided percutaneous method versus directly visualized surgical method. | LitMetric

Purpose: To compare complications in catheters placed by the fluoroscopically guided percutaneous method versus directly visualized surgery.

Materials And Methods: A retrospective cohort analysis was performed. Mechanical complication rate data, including catheter leakage, malfunction, malposition, and bleeding, were compared between the two groups over a 1-year follow-up period. Additionally, exit site infection rates, tunnel infection rates, and peritonitis episodes were evaluated based on the incidence within 30 days of insertion and 30 days to 1 year after insertion.

Results: A total of 101 patients were analyzed (52 in the fluoroscopic guidance group, 49 in the direct visualization group). Prevalence of diabetes was similar: 56% in the directly visualized surgery group and 47% in the fluoroscopically guided treatment group (P = .37). Although the difference was not significant, complication rates tended to be higher in the directly visualized surgery group compared with the percutaneous placement group. These included catheter leakage (13% vs 4%; P = .093), malfunction (11% vs 9%; P = .73), malposition (13% vs 6%; P = .20), and bleeding (8% vs 2%; P = .21). There were no differences in early and late exit site infections and tunnel infections. Late peritonitis rates were lower in the percutaneous placement group (20%) than in the direct visualization group (42%) (P = .018). Diabetic patients had approximately six times greater risk of catheter malfunction than nondiabetic patients regardless of method of catheter insertion.

Conclusions: Placement of peritoneal dialysis catheters percutaneously with fluoroscopic guidance is as safe as placement with direct visualization techniques.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvir.2008.05.006DOI Listing

Publication Analysis

Top Keywords

directly visualized
16
fluoroscopically guided
12
direct visualization
12
peritoneal dialysis
8
dialysis catheters
8
catheters fluoroscopically
8
guided percutaneous
8
percutaneous method
8
method versus
8
versus directly
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!