Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To compare complications in catheters placed by the fluoroscopically guided percutaneous method versus directly visualized surgery.
Materials And Methods: A retrospective cohort analysis was performed. Mechanical complication rate data, including catheter leakage, malfunction, malposition, and bleeding, were compared between the two groups over a 1-year follow-up period. Additionally, exit site infection rates, tunnel infection rates, and peritonitis episodes were evaluated based on the incidence within 30 days of insertion and 30 days to 1 year after insertion.
Results: A total of 101 patients were analyzed (52 in the fluoroscopic guidance group, 49 in the direct visualization group). Prevalence of diabetes was similar: 56% in the directly visualized surgery group and 47% in the fluoroscopically guided treatment group (P = .37). Although the difference was not significant, complication rates tended to be higher in the directly visualized surgery group compared with the percutaneous placement group. These included catheter leakage (13% vs 4%; P = .093), malfunction (11% vs 9%; P = .73), malposition (13% vs 6%; P = .20), and bleeding (8% vs 2%; P = .21). There were no differences in early and late exit site infections and tunnel infections. Late peritonitis rates were lower in the percutaneous placement group (20%) than in the direct visualization group (42%) (P = .018). Diabetic patients had approximately six times greater risk of catheter malfunction than nondiabetic patients regardless of method of catheter insertion.
Conclusions: Placement of peritoneal dialysis catheters percutaneously with fluoroscopic guidance is as safe as placement with direct visualization techniques.