Background: Although the common trunk of left pulmonary veins (PVs) has been reported as a relatively popular anatomical variation of PVs, little is known about the coalescence of contralateral PVs. The present study was conducted to reveal the prevalence and electrophysiologic characteristics of the confluent inferior common PVs.
Methods And Results: Anatomical variation in the PV drainage to the left atrium (LA) was assessed using the multidetector computed tomography scan in 326 patients with atrial fibrillation (AF) who underwent the PV isolation procedure. Coalescence of inferior PVs was observed in 5 cases (1.5%). Both inferior PVs conjoined prior to the junction with the LA in 3 cases, while they coalesced at the LA junction in the other 2 cases. The arrhythmogenic activities of the confluent inferior PVs were generally low in all cases without any ectopic firings triggering the observed AF. All inferior PVs, as well as the superior PVs, were successfully isolated either en bloc at the common trunk or individually at the orifice of each PV.
Conclusions: Confluent inferior PVs were present in 1.5% of cases in patients with AF who underwent the PV isolation procedure. Preoperative recognition of this venous anomaly by 3-dimensional imaging is important for smooth and safe ablation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1253/circj.72.1285 | DOI Listing |
Pacing Clin Electrophysiol
December 2024
Department of Cardiology, International University of Health and Welfare Hospital, Tochigi, Japan.
Background: Cryoballoon ablation has been widely performed in patients with paroxysmal atrial fibrillation (AF). In some challenging pulmonary veins (PVs), the procedure requires additional touch-up applications against the residual conduction gaps. It implies that there could exist difficult sites to cover with standard cryoballoon applications (CBAs), resulting in resistant conduction gaps (RCGs).
View Article and Find Full Text PDFArch Orthop Trauma Surg
December 2024
Department of Orthopedic Surgery and Traumatology, HFR Cantonal Hospital, University of Fribourg, Fribourg, Switzerland.
Introduction: The Gibson approach, used in hip-preserving surgery, is intermuscular and develops the space anteriorly to the gluteus maximus. Reliable anatomical landmarks for the development of this interval do not exist, but the interval is marked by perforating vessels (PV) of the inferior gluteal artery. The aim of this study was to provide reference values for the relationship between palpable anatomical landmarks on the femur/pelvis and the anterior border of the gluteus maximus using CT scans of the proximal femur.
View Article and Find Full Text PDFJ Clin Imaging Sci
October 2024
Department of Radiology, The Third Affiliated Hospital of Zunyi Medical University (The First People's Hospital of Zunyi), Zunyi, China.
Europace
November 2024
Faculty of Medicine and Surgery, Vita-Salute San Raffaele University, Via Olgettina 58, 20097 Milan, Italy.
Aims: The third-generation laser balloon (LB3) is an established ablation device for pulmonary vein isolation (PVI) that allows direct visualization of the anatomical target. Equipped with an automatic circumferential laser delivery modality, it aims at continuous circumferential PVI, improving both acute and clinical outcomes. We sought to evaluate the clinical efficacy of LB3 ablation using an anatomical-based approach without verifying electrical isolation.
View Article and Find Full Text PDFBackground: Currently, two types of cryoballoon (CB) systems are available for catheter ablation of atrial fibrillation (AF). Since the POLARx (Boston Scientific) is softer during freezing than the Arctic Front Advance Pro (AFA-Pro; Medtronic), it tends to go more deeply into the pulmonary vein (PV), risking PV stenosis.
Methods: Ninety-one patients underwent initial CB ablation for paroxysmal AF (AFA-Pro 56; POLARx 35).