Background: Although the common trunk of left pulmonary veins (PVs) has been reported as a relatively popular anatomical variation of PVs, little is known about the coalescence of contralateral PVs. The present study was conducted to reveal the prevalence and electrophysiologic characteristics of the confluent inferior common PVs.

Methods And Results: Anatomical variation in the PV drainage to the left atrium (LA) was assessed using the multidetector computed tomography scan in 326 patients with atrial fibrillation (AF) who underwent the PV isolation procedure. Coalescence of inferior PVs was observed in 5 cases (1.5%). Both inferior PVs conjoined prior to the junction with the LA in 3 cases, while they coalesced at the LA junction in the other 2 cases. The arrhythmogenic activities of the confluent inferior PVs were generally low in all cases without any ectopic firings triggering the observed AF. All inferior PVs, as well as the superior PVs, were successfully isolated either en bloc at the common trunk or individually at the orifice of each PV.

Conclusions: Confluent inferior PVs were present in 1.5% of cases in patients with AF who underwent the PV isolation procedure. Preoperative recognition of this venous anomaly by 3-dimensional imaging is important for smooth and safe ablation.

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.72.1285DOI Listing

Publication Analysis

Top Keywords

inferior pvs
20
confluent inferior
16
pvs
9
characteristics confluent
8
pulmonary veins
8
patients atrial
8
atrial fibrillation
8
common trunk
8
anatomical variation
8
underwent isolation
8

Similar Publications

Background: Cryoballoon ablation has been widely performed in patients with paroxysmal atrial fibrillation (AF). In some challenging pulmonary veins (PVs), the procedure requires additional touch-up applications against the residual conduction gaps. It implies that there could exist difficult sites to cover with standard cryoballoon applications (CBAs), resulting in resistant conduction gaps (RCGs).

View Article and Find Full Text PDF

Can surface landmarks help us identify the gibson interval during surgical hip dislocation: a study of 617 hips.

Arch Orthop Trauma Surg

December 2024

Department of Orthopedic Surgery and Traumatology, HFR Cantonal Hospital, University of Fribourg, Fribourg, Switzerland.

Introduction: The Gibson approach, used in hip-preserving surgery, is intermuscular and develops the space anteriorly to the gluteus maximus. Reliable anatomical landmarks for the development of this interval do not exist, but the interval is marked by perforating vessels (PV) of the inferior gluteal artery. The aim of this study was to provide reference values for the relationship between palpable anatomical landmarks on the femur/pelvis and the anterior border of the gluteus maximus using CT scans of the proximal femur.

View Article and Find Full Text PDF
Article Synopsis
  • The case describes a rare portal vein (PV) anomaly during embryonic development, specifically highlighting the presence of three distinct portal veins identified through CT venography.
  • The anatomical structure involves the superior and inferior mesenteric veins forming a trunk that splits into one vein entering the liver and another joining the splenic vein, which further divides into two branches entering the liver.
  • This report emphasizes the significance of understanding PV anatomy for surgical planning, as such duplications are extremely rare and can inform better clinical practices among healthcare professionals.
View Article and Find Full Text PDF

Aims: The third-generation laser balloon (LB3) is an established ablation device for pulmonary vein isolation (PVI) that allows direct visualization of the anatomical target. Equipped with an automatic circumferential laser delivery modality, it aims at continuous circumferential PVI, improving both acute and clinical outcomes. We sought to evaluate the clinical efficacy of LB3 ablation using an anatomical-based approach without verifying electrical isolation.

View Article and Find Full Text PDF

Background: Currently, two types of cryoballoon (CB) systems are available for catheter ablation of atrial fibrillation (AF). Since the POLARx (Boston Scientific) is softer during freezing than the Arctic Front Advance Pro (AFA-Pro; Medtronic), it tends to go more deeply into the pulmonary vein (PV), risking PV stenosis.

Methods: Ninety-one patients underwent initial CB ablation for paroxysmal AF (AFA-Pro 56; POLARx 35).

View Article and Find Full Text PDF