Objectives: The purpose of this study was to assess trends in endothelial coverage and recovery among leading polymer-based drug-eluting stents (DES).

Background: Autopsy studies of human U.S. Food and Drug Administration (FDA)-approved DES implanted coronary arteries suggest that complications of late stent thrombosis are associated with incomplete endothelial coverage of struts.

Methods: Rabbits received sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), and everolimus-eluting stents (EES) for 14 or 28 days along with MULTI-LINK (ML) Vision control stents. Endothelial coverage above and between struts was measured by morphometric analysis of images acquired through en face scanning electron microscopy. Dual fluorescent immunolabeling was performed for platelet-endothelial cell adhesion molecule (PECAM)-1 and thrombomodulin (TM), factors involved in cell-to-cell contact and thrombogenicity, respectively. In a separate analysis, the endothelial mitogen, vascular endothelial growth factor (VEGF), was also assessed.

Results: Varying rates of endothelialization among comparator DES were most notable at 14 days, where coverage above struts remained poor in SES, PES, and ZES (or=70%), whereas no significant differences were observed at 28 days. Select DES with poor endothelialization showed a further reduced expression of PECAM-1. All DES showed an absence or weak expression of the antithrombotic cofactor TM. Incomplete endothelialization in select DES was further associated with increased VEGF secretion and messenger ribonucleic acid levels at 14 days, providing evidence of a transitional healing surface.

Conclusions: The present study marks the first comparator analysis of endothelial coverage in leading polymeric DES, supporting disparities in arterial healing based on endothelial regrowth and recovery, favoring newer designs over the current generation of FDA-approved stents.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jacc.2008.04.030DOI Listing

Publication Analysis

Top Keywords

endothelial coverage
16
endothelial
8
polymer-based drug-eluting
8
stents
8
drug-eluting stents
8
coverage struts
8
analysis endothelial
8
select des
8
des
6
coverage
5

Similar Publications

Evaluation of endothelialization of an occluder device with cardiac computed tomography and assessment of the pathological validation.

PLoS One

January 2025

Department of Structural Heart Disease, Cardiovascular Institute and Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Background: Assessing the endothelialization of occlusive devices noninvasively remains a challenge. Cardiac computed tomography angiography (CTA) can be employed to evaluate device endothelialization based on contrast uptake within the occluder.

Objective: This study examined device endothelialization using cardiac CTA and investigated the pathological associations.

View Article and Find Full Text PDF

Enhanced Endothelialization Using Resveratrol-Loaded Polylactic Acid-Coated Left Atrial Appendage Occluders in a Canine Model.

ACS Appl Bio Mater

January 2025

State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences & Peking Union Medical College, Fuwai Hospital, 167 Beilishi Road, Xicheng District, Beijing 100037, China.

Left atrial appendage occlusion (LAAO) is a well-established alternative to anticoagulation therapy for patients with atrial fibrillation who have a high bleeding risk. After occluder implantation, anticoagulation therapy is still required for at least 45 days until complete LAAO is achieved by neoendocardial coverage of the device. We applied a polylactic acid-resveratrol coating to the LAAO membrane to enhance endothelialization with the goal of shortening the anticoagulation therapy duration.

View Article and Find Full Text PDF

Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted.

View Article and Find Full Text PDF

This study aimed to analyze the relationship between cutaneous microcirculation reactivity, retinal circulation, macrocirculation function, and specific adhesion molecules in young patients with uncomplicated type 1 diabetes. Fifty-five patients with type 1 diabetes mellitus (T1DM), aged 8 to 18 years, were divided into subgroups based on skin microcirculation reactivity. The cutaneous microcirculatory vessels were considered reactive if post-test PORH coverage increased compared to pre-test coverage.

View Article and Find Full Text PDF

Fibrin film on clots is increased by haematocrit but reduced by inflammation: implications for platelets and fibrinolysis.

J Thromb Haemost

January 2025

Discovery and Translational Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.

Background: Blood clot formation, triggered by vascular injury, is crucial for haemostasis and thrombosis. Blood clots are composed mainly of fibrin fibres, platelets and red blood cells (RBCs). Recent studies show that clot surface also develops a fibrin film, which provides protection against wound infection and retains components such as RBCs within the clot.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?