Purpose: An extensive body of literature demonstrates a strong correlation between intervertebral disk (IVD) hydration status (HS) and functional spinal integrity. However, to date, in vivo IVD HS assessment has relied largely on subjective and nonrepeatable measures. The aim of this study was to establish the consistency of signal homogeneity of a novel semisolid-state manganese chloride (MnCl2)-based phantom for HS correlation using conventional magnetic resonance (MR) imaging.

Materials And Methods: Sixteen MnCl2 phantoms, of increasing relative molar concentration (range 0.01 to 2.9 mM), underwent axial MR imaging. Phantom signal-to-noise ratio measures were recorded for each concentration on several sequence types. Coefficient of variance data were calculated to determine the degree of MR signal variation at each concentration.

Results: Analysis of variance testing suggested no significant difference in coefficient of variance data derived from phantom signal intensities using either T1- (P = .13) or T2-weighted sequence types (P = .96), suggesting a high degree of relative signal homogeneity.

Conclusions: The findings of this study suggest that a MnCl2 phantom combined with a nonfield reactive, semirigid, gelatin suspension media can produce a predictable, concentration-related, homogeneous MR signal response. This may be an appropriate base material for a noninvasive model to allow accurate quantification of the hydration status of the in vivo human IVD.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hydration status
12
sequence types
8
coefficient variance
8
variance data
8
signal
5
determining disk
4
disk hydration
4
status mncl2-based
4
mncl2-based model
4
model purpose
4

Similar Publications

The aim was to estimate the prevalence of low muscle mass (LMM) and low muscle mass associated with obesity (LMM-O) in healthy adult, and to verify the performance of raw bioelectrical impedance parameters (BIA) and vector analysis (BIVA) in the screening of this tow conditions. This is a cross-sectional study including 1025 healthy adults. Body composition was assessed by the BIA technique.

View Article and Find Full Text PDF

Perioperative fluid therapy is a pivotal component of surgical patient management, as appropriate fluid administration can significantly enhance postoperative recovery. To standardize perioperative fluid therapy for adult patients in China, the Geriatric Anesthesia and Perioperative Management Group of the Chinese Society of Anesthesiology has developed the "Clinical Practice Guidelines for Perioperative Fluid Therapy in Chinese Adult Patients". Based on current clinical status in China, this guideline addressed 11 key areas based on clinical evidence, more than 30% of which is from China researchers, including principles for the selection of common fluid types, preoperative fasting and hydration following enhanced recovery after surgery (ERAS) protocols, intraoperative fluid requirements for adult patients, perioperative volume assessment, perioperative evaluation of volume overload/insufficiency, goal-directed fluid therapy, restrictive fluid therapy, perioperative fluid therapy strategies for high-risk patients, fluid resuscitation for massive blood loss, the relationship between perioperative fluid therapy and postoperative complications, and the relationship between perioperative fluid therapy and ERAS.

View Article and Find Full Text PDF

Menstrual cycle effects on thermoregulation while exercising in the heat.

J Therm Biol

January 2025

School of Integrative Physiology and Athletic Training, University of Montana, 32 Campus Drive, Missoula, MT, 59812, USA. Electronic address:

Women may be challenged to maintain thermoregulation due to hormonal changes associated with the menstrual cycle. The purpose of this study was to assess the effect of the menstrual cycle phase on core temperature, hydration status, and perceived exertion while exercising under uncompensable heat gain. Eleven eumenorrheic women (24.

View Article and Find Full Text PDF

Bioelectrical Impedance Vector Analysis (BIVA) is a valuable tool for evaluating hydration and body composition, but its application in subacute post-stroke patients remains unexplored. This study aimed to fill this gap by analyzing BIVA in a cohort of 87 subacute post-stroke patients (42 women, mean age 69 ± 12) undergoing rehabilitation. At admission (T0), diagnosis of malnutrition with GLIM criteria and of sarcopenia with EWGSOP2 was done, and patients were analyzed with BIVA.

View Article and Find Full Text PDF

Background: Accurate body fat distribution assessment is essential for managing cardiovascular disease and metabolic disorders. Although several methods are available for segmental fat analysis, few studies have examined the validity of affordable methods such as Bioelectrical Impedance Analysis (BIA) against the reference method, Dual-Energy X-ray Absorptiometry (DXA). This study aimed to assess the validity of BIA as compared to DXA for segmental fat mass assessment, and to develop anthropometric multivariate regression models that offer a cost-effective alternative for health professionals in clinical and public health settings.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!