Background: Ultrasound perfusion imaging (UPI) is a new approach for the assessment of brain perfusion. In contrast to the increasing experience with this method in patients with ischemic stroke, data on the value of UPI for the diagnosis of intracerebral hemorrhage (ICH) are lacking.

Methods: We investigated 12 consecutive patients with sufficient temporal bone windows and a CT diagnosis of acute supratentorial ICH (basal ganglia n = 9 and lobar n = 3). Native transcranial B-mode ultrasound and UPI studies with echo contrast agents were performed on day 1 and on days 5-7 including volume measurements using the maximum extension on transverse and coronal ultrasound planes.

Results: ICH was identified as hyperechogenic mass on B-mode ultrasound in 11/12 patients, but the correlation with CT volume measurements was poor (day 1: r = 0.4, 95% confidence interval, CI: -0.23-0.79; p = 0.1; follow-up: r = 0.58, 95% CI: 0.04-0.86; p = 0.21). Volume measurement was more precise using UPI with a significant correlation on day 1 (r = 0.8, 95% CI: 0.47-0.94; p < 0.001) and during the follow-up (r = 0.94, 95% CI: 0.81-0.98; p < 0.001). Using UPI the typical finding was a focal reduction of contrast agent arrival in the ICH core which led to better delineation of the lesion borders from adjacent tissue. Depiction of lobar ICH was difficult with ultrasound, and lesion sizes tended to be underestimated.

Conclusions: This study supports earlier work demonstrating the usefulness of native transcranial ultrasound for the diagnosis of ICH. UPI further improves diagnostic reliability and allows very precise ICH volume measurements. If confirmed in larger studies, this approach may be useful for bedside monitoring of ICH progression and regression.

Download full-text PDF

Source
http://dx.doi.org/10.1159/000147456DOI Listing

Publication Analysis

Top Keywords

volume measurements
12
intracerebral hemorrhage
8
transcranial ultrasound
8
ultrasound perfusion
8
perfusion imaging
8
ich
8
native transcranial
8
b-mode ultrasound
8
day 95%
8
ultrasound
7

Similar Publications

Fatigue cracking of rib-to-deck conventional single-sided welded joints is a prevalent issue in orthotropic steel decks (OSDs), significantly impacting their structural integrity and durability. Rib-to-deck innovative double-sided welded joints have the potential to enhance the fatigue resistance of OSD. However, Welding Residual Stresses (WRS) significantly influence the fatigue life of these joints, mandating its consideration in fatigue assessments.

View Article and Find Full Text PDF

Added safety measures coupled with the development and use of pathogen reduction technologies (PRT) significantly reduces the risk of transfusion-transmitted infections (TTIs) from blood products. Current approved PRTs utilize chemical and/or UV-light based inactivation methods. While the effectiveness of these PRTs in reducing pathogens are well documented, these can cause tolerable yet unintended consequences on the quality and efficacy of the transfusion products.

View Article and Find Full Text PDF

Collapsible loess soils, known for their significant volume reduction upon the wetting, pose critical challenges in the geotechnical engineering. The estimation of the wetting-induced settlement is crucial for the foundation design and the determination of the negative skin friction on the pile. In this paper, a new method is proposed to estimate the wetting induced collapse from the wetting soil-water characteristic curve (SWCC) and the index properties of the loess soils.

View Article and Find Full Text PDF

Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.

View Article and Find Full Text PDF

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!