Ionization efficiencies and fragmentation patterns of cyanoacrylate ultraviolet (UV) absorbers, Uvinul 3035 and Uvinul 3039, were studied using liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS). Solvent effect on the ionization efficiencies was investigated using methanol, ethanol, acetone, and chloroform. The fragmentation patterns were also investigated by varying the fragmentor voltage. Solvated ions, the [M+H + solvent](+) of methanol, ethanol, and acetone were detected, but the [M+H + chloroform](+) ion was not observed. For Uvinul 3039 in chloroform, the [M+CHCl(2)](+) ion was detected instead of the solvated ion. Relative abundance of the solvated ion was decreased by increasing the fragmentor voltage. Fragment ions of m/z 250, 232, and 204 were detected and their abundance increased with an increase in the fragmentor voltage. The m/z 250 ion can be accounted for by a McLafferty rearrangement. The fragment ions of m/z 232 and 204 were formed not only by subsequent fragmentations of the m/z 250 ion, but also by ion-molecule reactions of solvent ion and neutral analyte.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/rcm.3650 | DOI Listing |
Talanta
April 2025
Applied Analytical Chemistry, University of Duisburg-Essen, Universitatsstr. 5, 45141, Essen, Germany; Teaching and Research Center for Separation, University of Duisburg-Essen, Universitatsstr. 5, 45141, Essen, Germany. Electronic address:
The monitoring of phthalate esters (PAEs) is challenging due to background contamination as well as the low selectivity observed when analyzing them by gas chromatography coupled to mass spectrometry (GC-MS) using electron ionization (EI). In this sense, alternative and soft ionization techniques could help to enhance the performance of the analytical determinations of PAEs in food samples. In this work, the use of a novel and soft ionization technique tube plasma ionization (TPI) has been explored to enhance the selectivity and sensitivity in the determination of PAEs in drinking water samples with GC-MS.
View Article and Find Full Text PDFJ Chromatogr A
January 2025
Instituto de Química Orgánica General (IQOG-CSIC), Juan de la Cierva 3, 28006 Madrid, Spain. Electronic address:
Zhongguo Zhong Yao Za Zhi
June 2024
National Key Laboratory of Chinese Medicine Modernization, Key Laboratory of Chinese Pharmacology of the Ministry of Education, Tianjin University of Traditional Chinese Medicine Tianjin 301617, China.
Anal Chim Acta
May 2024
Department of Food Science and Agricultural Chemistry, McGill University, Ste-Anne-de-Bellevue, QC, Canada. Electronic address:
Honeys of particular botanical origins can be associated with premium market prices, a trait which also makes them susceptible to fraud. Currently available authenticity testing methods for botanical classification of honeys are either time-consuming or only target a few "known" types of markers. Simple and effective methods are therefore needed to monitor and guarantee the authenticity of honey.
View Article and Find Full Text PDFJ Mass Spectrom
December 2023
Department of Chemistry, Sejong University, Seoul, Republic of Korea.
Dinitrotoluenes (DNTs) and nitrotoluenes (NTs) are found in the environment as metabolites of trinitrotoluene (TNT). When acetone is used as the solvent/eluent in atmospheric pressure chemical ionization-mass spectrometry (APCI-MS), the reactant ion is [2Acetone + O ] for the negative ion mode. The reactant ion reacts with an analyte to produce M and/or [M - H] under atmospheric pressure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!