The purpose of this study was to compare daily couch shifts after prostate localization between megavoltage CT (MVCT, Hi-ART TomoTherapy) and b-mode ultrasound (BAT system). Nine hundred and thirteen couch shifts from 22 consecutive patients treated using MVCT localization were compared to 853 shifts from 23 randomly selected patients treated using b-mode ultrasound prostate localization. Shifts were made in three principal axes based on prostate position after comparing daily images to the initial planning CT. Mean shift for each axis and the shift variability both between and within individual subjects were calculated. Variability was higher for BAT compared to MVCT for vertical and cranial-caudal (CC) shifts (p=0.0084 and 0.01037, respectively), while lateral shifts were significantly greater for MVCT. For each individual, the pairwise correlations between shifts in different axes were calculated. Among all the groups and pairings, only the pairing of vertical and cranial/caudal adjustments in BAT-localized patients showed significant evidence of correlation after adjustment for multiple pairwise comparisons (p=0.0006). When compared to MVCT, the use of BAT for prostate localization results in greater variability of positional adjustments in vertical and CC directions. This likely reflects differences in the ability to precisely align b-mode ultrasound contours to KVCT images, as well as prostate excursion in vertical and CC direction caused by the ultrasound probe. These considerations need to be made when defining treatment volumes, and argue for the use of less disruptive techniques for daily prostate localization.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3634324 | PMC |
http://dx.doi.org/10.1177/153303460800700402 | DOI Listing |
J Imaging Inform Med
January 2025
Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan.
Non-alcoholic fatty liver disease (NAFLD) is a highly prevalent chronic liver condition characterized by excessive hepatic fat accumulation. Early diagnosis is crucial as NAFLD can progress to more severe conditions like steatohepatitis, fibrosis, cirrhosis, and hepatocellular carcinoma without timely intervention. While liver biopsy remains the gold standard for NAFLD assessment, abdominal ultrasound (US) imaging has emerged as a widely adopted non-invasive modality due to convenience and low cost.
View Article and Find Full Text PDFJ Ultrasound Med
January 2025
Department of Radiology, University of Michigan Health System, Ann Arbor, Michigan, USA.
Objective: Focused ultrasound has emerged as a precise and minimally invasive modality for effective cancer treatment. In this study, we propose a novel method that integrates the mechanical effects of focused ultrasound, known as histotripsy, with heating to enhance both the immediate and sustained cytotoxic effects on cancer cells.
Methods: Our investigation focused on VX2 cancer cells in suspension, examining five experimental groups: blank control, negative control, heating alone, histotripsy alone, and histotripsy with subsequent heating.
Cureus
December 2024
Department of Pediatrics, Japanese Red Cross Wakayama Medical Center, Wakayama, JPN.
Acute ischemic stroke, a medical emergency caused by reduced cerebral blood flow, results in brain cell damage. While commonly associated with older individuals, strokes can also occur in young and middle-aged adults, posing significant socio-economic and health challenges due to the long-term impact of the condition. This poses significant socio-economic and health challenges because stroke is a leading cause of disability and mortality.
View Article and Find Full Text PDFTheriogenology
January 2025
UEL - Universidade Estadual de Londrina, Londrina, PR, Brazil. Electronic address:
This study compared the reproductive performance of three different programs using conventional fixed-time artificial insemination (FTAI), fixed-time embryo transfer (FTET), and their combined use, considering estrus intensity as a criterion for the reproductive program. Brangus multiparous cows (n = 1.100), 40-50 days postpartum, 4-8 years old, and body condition scores 2.
View Article and Find Full Text PDFEndocrine
January 2025
Center for Advanced Ultrasound Evaluation, Dr. D Medical Center, Timisoara, Romania.
Purpose: Shear wave elastography (SWE) is a valuable tool in discerning the malignancy risk of thyroid nodules. This study investigates whether 2D-SWE can reliably differentiate malignant thyroid nodules in patients with chronic autoimmune thyroiditis (CAT), despite the challenges posed by fibrosis, which can increase tissue stiffness and complicate diagnosis.
Methods: This retrospective observational study evaluated 130 thyroid nodules (91 benign, 39 malignant) in patients with underlying CAT using conventional ultrasound (B-mode) and 2D-SWE with SuperSonic Mach30 equipment (Supersonic Imagine, Aix-en-Provence, France).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!