A Doppler global velocimetry (DGV) measurement technique with a sinusoidal laser frequency modulation is presented for measuring velocity fields in fluid flows. A cesium absorption cell is used for the conversion of the Doppler shift frequency into a change in light intensity, which can be measured by a fiber coupled avalanche photo diode array. Because of a harmonic analysis of the detector element signals, no errors due to detector offset drifts occur and no reference detector array is necessary for measuring the scattered light power. Hence, large errors such as image misalignment errors and beam split errors are eliminated. Furthermore, the measurement system is also capable of achieving high measurement rates up to the modulation frequency (100 kHz) and thus opens new perspectives to multiple point investigations of instationary flows, e.g., for turbulence analysis. A fundamental measurement uncertainty analysis based on the theory of Cramér and Rao is given and validated by experimental results. The current relation between time resolution and measurement uncertainty, as well as further optimization strategies, are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.47.003941DOI Listing

Publication Analysis

Top Keywords

measurement uncertainty
12
doppler global
8
global velocimetry
8
laser frequency
8
frequency modulation
8
measurement
6
uncertainty temporal
4
temporal resolution
4
resolution doppler
4
velocimetry laser
4

Similar Publications

Extending from Adaptation to Resilience Pathways: Perspectives from the Conceptual Framework to Key Insights.

Environ Manage

January 2025

TECNALIA Research & Innovation, Basque Research and Technology Alliance (BRTA), Energy, climate, and urban transition, Parque Tecnológico de Bizkaia, Derio, Spain.

The extent and timescale of climate change impacts remain uncertain, including global temperature increase, sea level rise, and more frequent and intense extreme events. Uncertainties are compounded by cascading effects. Nevertheless, decision-makers must take action.

View Article and Find Full Text PDF

ARCH: Large-scale knowledge graph via aggregated narrative codified health records analysis.

J Biomed Inform

January 2025

Harvard T.H. Chan School of Public Health, 677 Huntington Ave, Boston, 02115, MA, USA; VA Boston Healthcare System, 150 S Huntington Ave, Boston, 02130, MA, USA. Electronic address:

Objective: Electronic health record (EHR) systems contain a wealth of clinical data stored as both codified data and free-text narrative notes (NLP). The complexity of EHR presents challenges in feature representation, information extraction, and uncertainty quantification. To address these challenges, we proposed an efficient Aggregated naRrative Codified Health (ARCH) records analysis to generate a large-scale knowledge graph (KG) for a comprehensive set of EHR codified and narrative features.

View Article and Find Full Text PDF

Aim: To explore the meaning of adaptation after visceral transplantation in terms of patient experiences, symptoms, self-efficacy, transplant-specific and mental well-being.

Design: A convergent parallel mixed-methods study, consisting of interviews and generic as well as transplant-specific questionnaires. Results were integrated using meta-inference.

View Article and Find Full Text PDF

The effective knowledge of emissivity is pivotal to obtain reliable temperature measurements through non-contact techniques like pyrometry and thermal imaging. This is fundamental in high-temperature applications since material emissivity strongly depends on temperature conditions. Given the recent attention in high-temperature applications, especially for replacing fossil-fuel-dependent heating with greener solutions in energy-intensive processes, renewed interest in characterizing materials radiant properties rose.

View Article and Find Full Text PDF

On the Measurement of Laser Lines in 3D Space with Uncertainty Estimation.

Sensors (Basel)

January 2025

InViLab, Department of Electromechanical Engineering, University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium.

Laser-based systems, essential in diverse applications, demand accurate geometric calibration to ensure precise performance. The calibration process of the system requires establishing a reliable relationship between input parameters and the corresponding 3D description of the outgoing laser beams. The quality of the calibration depends on the quality of the dataset of measured laser lines.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!