A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of assessment of native coronary arteries by standard versus three-dimensional coronary angiography. | LitMetric

Vessel foreshortening is a major limitation of standard coronary angiography due to the 2-dimensional representation of 3-dimensional structures. Three-dimensional models may overcome it. The aim of this study was to compare measurements of coronary segments from quantitative coronary angiography (QCA) in an operator-selected "working view" of standard 2-dimensional coronary angiography with those from 3-dimensional coronary angiography (3D-CA) reconstruction models, which are automatically generated from software applied to rotational coronary angiographic acquisitions. Patients who underwent percutaneous coronary intervention were considered. Two or 3 segments of the artery needing treatment were prespecified, using bifurcations as edges. The operator selected a working view from standard angiography as the view best representing each segment. Rotational angiography was performed, allowing 3-dimensional reconstruction of the selected segments. Additionally a marker guidewire (with 4 markers 10 mm away from one another at the distal tip) was used to further measure segment length, and it was considered the "gold standard" reference. In 36 patients, 81 segments from 12 left anterior descending, 12 circumflex, and 12 right coronary arteries were evaluated. Three-dimensional coronary angiography was always feasible. Although reference vessel diameter was not different between 3D-CA and QCA (p >0.05), segment length measurements were on average 2.3 +/- 2.5 mm longer with 3D-CA than with QCA (p <0.001) and 0.4 +/- 1.8 mm longer than with marker guidewire measurement (p = 0.047). Marker guidewire measurements were 1.9 +/- 2.8 mm longer than QCA measurements (p <0.001). According to Bland-Altman plots, 3D-CA and marker guidewire measurements had the best agreement. In conclusion, 3-dimensional coronary modeling is highly feasible and yields more accurate assessments of the lengths of coronary segments than standard QCA.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2008.03.048DOI Listing

Publication Analysis

Top Keywords

coronary angiography
24
coronary
11
coronary arteries
8
three-dimensional coronary
8
angiography
8
segment length
8
3d-ca qca
8
comparison assessment
4
assessment native
4
native coronary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!