Objective: Assess the performance of self-expanding venous cannulas for routine use in open-heart surgery.

Methods: Prospective study in 100 unselected consecutive patients undergoing open-heart surgery with either remote or central smart venous cannulation.

Results: The study focuses on the 76 consecutive adult patients (mean age 59.2+/-17.3 years; 60 males, 16 females) undergoing surgical procedures with total cardiopulmonary bypass for either valve procedures (42/76 patients=55.3%), ascending aorta and arch repair (20/76 patients=26.3%), coronary artery revascularization (13/76 patients=17.1%) or other procedures (11/76 patients=14.5%) with 14/76 patients (18.4%) undergoing redo surgery and 6/76 patients (7.9%) undergoing small access surgery. The mean pump flow achieved by gravity drainage alone accounted for 5.0+/-0.6l/min (=114% of target) in the entire study population (n=76) as compared to the calculated, theoretical pump flow of 4.4+/-0.5l/min (p<0.0001). For the femoral cannulation sub-group (n=35) pump flow achieved by gravity drainage alone accounted for 4.9+/-0.6l/min (=114% of target) as compared to the calculated theoretical pump flow of 4.3+/-0.4l/min (p<0.0001). The corresponding numbers for trans-subclavian cannulation (n=7) are 5.2+/-0.5l/min (111%) for the pump flow achieved by gravity drainage as compared to the theoretical target flow of 4.7+/-0.4l/min. For the central cannulation sub-group (n=34) mean flow achieved by gravity drainage with a self-expanding venous cannula accounted for 5.1+/-0.7l/min (=116% of target) as compared to the calculated theoretical flow of 4.4+/-0.6l/min (p<0.0001).

Conclusion: Full or more than target flow was achieved in 97% of the patients studied undergoing CPB with self-expanding venous cannulas and gravity drainage. Remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. Augmentation of venous return is no longer necessary.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejcts.2008.05.037DOI Listing

Publication Analysis

Top Keywords

self-expanding venous
8
venous cannulas
8
cardiopulmonary bypass
8
pump flow
8
routine self-expanding
4
cannulas cardiopulmonary
4
bypass benefits
4
benefits pitfalls
4
pitfalls 100
4
100 consecutive
4

Similar Publications

Letter to the Editor on "Newly Designed, Self-Expanding Large-Bore Nitinol Stents for Symptomatic Central Venous Stenosis: Technical and Long-Term Clinical Outcome".

Cardiovasc Intervent Radiol

December 2024

Department of Pulmonary and Critical Care Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, 510080, Guangdong, China.

View Article and Find Full Text PDF

Background: Endovascular recanalization with venous stenting is the preferred treatment for iliofemoral venous obstruction. We reviewed our institutional experience and mid-term outcomes with endovascular therapy for iliofemoral venous obstruction using the Venovo Self-expanding Venous Stent (BARD Peripheral Vascular, Inc., Tempe, AZ, USA).

View Article and Find Full Text PDF
Article Synopsis
  • Idiopathic intracranial hypertension (IIH) is a condition with high brain pressure that can severely affect vision, and its cause is often unknown.
  • Recent studies suggest that venous sinus stenting (VSS) may be an effective treatment, as demonstrated by two young women who experienced quick relief from visual problems after the procedure.
  • Both patients showed elevated cerebrospinal fluid pressure and narrowed transverse sinuses, and after using stents to widen these sinuses, their symptoms and papilledema improved significantly right away.
View Article and Find Full Text PDF

The VIVID trial 12-month outcomes of the venous stent for the iliofemoral vein using the Duo venous stent system.

J Vasc Surg Venous Lymphat Disord

October 2024

Department of Interventional Radiology, Endovascular Consultants, Wilmington, NC.

Objective: There are varying anatomical and mechanical demands of stent placement in the iliofemoral venous segment; the Duo Venous Stent System is designed to address these issues. The purpose of the VIVID (Venous stent for the Iliofemoral Vein Investigational clinical trial using the Duo Venous Stent System) study was to investigate the safety and efficacy of the Duo Venous Stent System for the treatment of patients with nonmalignant iliofemoral venous obstructive disease.

Methods: This was an international, prospective, multicenter, single-arm study that enrolled patients with symptomatic nonthrombotic (NT), post-thrombotic (PTS), or acute deep vein thrombotic (aDVT) iliofemoral venous outflow obstruction.

View Article and Find Full Text PDF
Article Synopsis
  • * A total of 103 patients, mostly with stenotic issues in the upper arm, showed high technical and clinical success rates, with favorable patency rates at 6 months.
  • * The research found low rates of adverse events (≤3%) and no device deficiencies, supporting the use of this stent graft as a safe and effective option for patients experiencing vascular access graft problems.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!