Unlabelled: Remote Magnetic Mapping After Mustard/Senning Procedure.

Introduction: Mapping of intraatrial reentrant tachycardia (IART) still presents a challenge in complex congenital heart disease. The goal of this work was to present our initial experience with remote magnetic navigation (RMN) for mapping of IART in four patients after the atrial switch procedure (Mustard n = 1, Senning n = 3) for d-transposition of the great arteries.

Methods: Three-dimensional (3D) mapping of the systemic venous atrium and the pulmonary venous atrium (PVA) was performed using RMN (Niobe) in conjunction with 3D mapping (CartoRMT). The maps were fused with a CT-based 3D anatomy.

Results: All patients had cavotricuspid isthmus-dependent IART with a mean atrial cycle length of 305 ms. Mapping of both atria (PVA retrogradely by passing the aortic and tricuspid valve) was feasible and safe. The procedure time for IART mapping ranged from 210 to 320 minutes with a mean of 251 minutes. The fluoroscopy time for IART mapping ranged from 15.8 to 45.0 minutes (mean 31.6 minutes) for patients, and ranged from 12.3 to 24.3 minutes with a mean of 19.5 minutes for physicians. No procedural complications occurred.

Conclusion: Precise mapping of IART in the complex anatomical structures after an atrial switch procedure was feasible and safe using RMN. The maneuverability of the catheter was possible even with a retrograde access crossing two valves. Further reduction of procedural and fluoroscopy times for both patients and physicians seems possible.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8167.2008.01231.xDOI Listing

Publication Analysis

Top Keywords

remote magnetic
12
mapping
10
mapping intraatrial
8
intraatrial reentrant
8
magnetic navigation
8
d-transposition great
8
mustard senning
8
mapping iart
8
atrial switch
8
switch procedure
8

Similar Publications

Remotely induced electrical modulation of deep brain circuits in non-human primates.

Front Hum Neurosci

December 2024

Department of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.

Introduction: The combination of magnetic and focused ultrasonic fields generates focused electric fields at depth entirely noninvasively. This noninvasive method may find particularly important applications in targeted treatments of the deep brain circuits involved in mental and neurological disorders. Due to the novelty of this method, it is nonetheless unknown which parameters modulate neural activity effectively.

View Article and Find Full Text PDF

Dendritic cells (DCs) play a crucial role in initiating antitumor immune responses. However, in the tumor environment, dendritic cells often exhibit impaired antigen presentation and adopt an immunosuppressive phenotype, which hinders their function and reduces their ability to efficiently present antigens. Here, a dual catalytic oxide nanosponge (DON) doubling as a remotely boosted catalyst and an inducer of programming DCs to program immune therapy is reported.

View Article and Find Full Text PDF

An MRI-guided stereotactic neurosurgical robotic system for semi-enclosed head coils.

J Robot Surg

December 2024

National Engineering Research Center of Neuromodulation, School of Aerospace Engineering, Tsinghua University, Beijing, 100084, China.

Magnetic resonance imaging (MRI) offers high-quality soft tissue imaging without radiation exposure, which allows stereotactic techniques to significantly improve outcomes in cranial surgeries, particularly in deep brain stimulation (DBS) procedures. However, conventional stereotactic neurosurgeries often rely on mechanical stereotactic head frames and preoperative imaging, leading to suboptimal results due to the invisibility and the contact with patient's head, which may cause additional harm. This paper presents a frameless, MRI-guided stereotactic neurosurgical robotic system.

View Article and Find Full Text PDF

Urinary biomarker studies in cardiothoracic and kidney-sparing surgery have demonstrated renal protection by Remote Ischaemic PreConditioning (RIPC). RIPC intervention generates cycles of ischaemia and reperfusion of the limbs before the actual ischaemia of the target organ (e.g.

View Article and Find Full Text PDF

The ground-based solar telescope THEMIS performed several observations of Mercury's sodium exosphere in years 2011-2013, when the MESSENGER spacecraft was orbiting around the planet. Typical two-peak exospheric patterns were frequently identified. In previous studies, some specific cases of THEMIS Na two-peak observations were characterized and related to IMF conditions, during specific extreme cases, in the occasion of CME arrival.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!