Separation of enzymes from microorganism crude extracts by free-flow zone electrophoresis.

Biotechnol Bioeng

Department of Biochemical Engineering and Biotechnology, Indian Institute of Technology, Hauz Khas, New Delhi 110 016, India.

Published: July 1996

Continuous, single-step, state-of-the-art preparative separations of enzymes from microorganism crude extracts by free-flow zone electrophoresis are presented. In the first example, the enzymes formate dehydrogenase, formaldehyde dehydrogenase, and methanol oxidase were continuously separated from Candida boidinii crude extract. Yields of 85% to 95% and purification factors between 3 and 7 were obtained along with a simultaneous separation of the finer cell debris from the enzymes. Using multiple injections of sample, a throughput of 46.2 mg protein/h was recorded. In the second example, a fivefold purification of beta-galactosidase from Escherichia coli was achieved along with complete, simultaneous cell debris separation from the enzyme. The yield of the enzyme was greater than 90%. The preparative free-flow zone electrophoresis experiments were run continuously for a period of 12 h and the separations were found to be stable; i.e., the enzymes and the cell debris eluted at their respective fraction numbers during the entire period. In both examples, choice of the type of buffer played a critical role and had to be investigated and optimized experimentally. Scale-up aspects of the separations are also discussed. Recently, by comparison of free-flow zone electrophoresis with ion-exchange chromatography, we have presented evidence that free-flow electrophoresis separations are governed by net surface charge (S. Nath et al., Biotechnol. Bioeng. 1993, 42: 829-835). Here, we offer further confirmation of this evidence by comparison of preparative free-flow zone electrophoresis experiments at various pHs on a mixture of two model proteins with analytical electrophoretic titration curves of the proteins. We are thus in a position to predict separations in free-flow zone electrophoresis. (c) 1996 John Wiley & Sons, Inc.

Download full-text PDF

Source
http://dx.doi.org/10.1002/(SICI)1097-0290(19960705)51:1<15::AID-BIT2>3.0.CO;2-3DOI Listing

Publication Analysis

Top Keywords

free-flow zone
24
zone electrophoresis
24
cell debris
12
enzymes microorganism
8
microorganism crude
8
crude extracts
8
extracts free-flow
8
preparative free-flow
8
electrophoresis experiments
8
free-flow
7

Similar Publications

Unlabelled: In this study, we evaluated and forecasted the cumulative opportunities for residents to access radiotherapy services in Cali, Colombia, while accounting for traffic congestion, using a new people-centred methodology with an equity focus. Furthermore, we identified 1-2 optimal locations where new services would maximise accessibility. We utilised open data and publicly available big data.

View Article and Find Full Text PDF

Preparation of Highly Enriched ER Membranes Using Free-Flow Electrophoresis.

Methods Mol Biol

February 2024

Department of Biochemistry, Cambridge University, Cambridge, UK.

Free-flow electrophoresis (FFE) is a technique for separation of proteins, peptides, organelles, and cells. With zone electrophoresis (ZE-FFE), organelles are separated according to surface charge. The ER is the only remaining major cellular compartment in Arabidopsis not to have been isolated using density centrifugation, immune-isolation, or any other method previously applied to purification of plant membranes.

View Article and Find Full Text PDF

Aims: To confirm the improved performance of the micro-hole zone catheter (MHZC) compared to a conventional eyelet catheter (CEC) in male users of clean intermittent catheterizations (CICs).

Methods: Male self-catheterizing subjects, who used hydrophilic sleeved soft/flexible CIC as the only bladder emptying method, were enrolled into a multi-center, randomized, cross-over study performed across six European sites. Subjects tested the MHZC, featuring a drainage zone with 120 micro-holes and a CEC with two eyelets.

View Article and Find Full Text PDF

The broadening of analyte streams, as they migrate through a free-flow electrophoresis (FFE) channel, often limits the resolving power of FFE separations. Under laminar flow conditions, such zonal spreading occurs due to analyte diffusion perpendicular to the direction of streamflow and variations in the lateral distance electrokinetically migrated by the analyte molecules. Although some of the factors that give rise to these contributions are inherent to the FFE method, others originate from non-idealities in the system, such as Joule heating, pressure-driven crossflows, and a difference between the electrical conductivities of the sample stream and background electrolyte.

View Article and Find Full Text PDF
Article Synopsis
  • * The paper reviews advancements in microchip materials, including silicon and various polymers, and discusses challenges in manufacturing costs, processing times, and lifespan that hinder widespread industrial use.
  • * Moreover, the research focuses on improving surface modification methods for polymer channels and the materials used for electrodes, highlighting the need for better approaches to enhance experimentation and effectiveness in microchip electrophoresis.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!