A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A feasibility study of computer-assisted bone graft implantation for tissue-engineered replacement of the human ankle joint. | LitMetric

Objective: Computer-assisted graft implantation may contribute to achieving biological joint replacement in the future. The purpose of this experimental study was to evaluate the feasibility and accuracy of a series of computer-assisted graft implantations into human cadaver ankle joints.

Methods: Three-dimensional graft models of virtually planned corresponding tibial and talar defects were created from bovine cancellous bone. A platform for computer-assisted surgery (CAS) was set up to implant the grafts. Registration was performed by pair-point matching with anatomical landmarks. In the case of insufficient registration accuracy, artificial landmarks were used for registration. Eight grafts (four tibial, four talar) were implanted in four human cadaver ankle joints. Postoperative CT was used for outcome analysis. The following criteria of accuracy were defined: macroscopic quality of implant fit; quality of the sagittal and coronar joint surface; and quality of the undersurface of the graft in relation to the base of the defect.

Results: No technical complications were observed during computer-assisted graft implantation. Clinically acceptable accuracy was achieved in 6 of 8 graft implantations, with implant failure occurring at the tibial and talar location in one ankle joint. In total, 25 of 32 criteria of accuracy were achieved: 6/8 for macroscopic implant fit; 5/8 for quality of the sagittal joint surface; 7/8 for quality of the coronar joint surface; and 7/8 for quality of the undersurface of the graft. Registration with anatomical landmarks did not achieve sufficient accuracy in 4 of 8 cases, whereas registration with artificial landmarks was successful in all these cases.

Conclusions: We demonstrated the feasibility and accuracy of computer-assisted graft implantation for tissue-engineered replacement of the human ankle joint. However, we cannot recommend the present type of registration by pair-point matching with anatomical landmarks due to the considerable inaccuracies. The focus should be on the improvement of non-invasive registration techniques and methods for evaluating postoperative outcome.

Download full-text PDF

Source
http://dx.doi.org/10.3109/10929080802210814DOI Listing

Publication Analysis

Top Keywords

graft implantation
16
computer-assisted graft
16
ankle joint
12
tibial talar
12
anatomical landmarks
12
joint surface
12
graft
9
implantation tissue-engineered
8
tissue-engineered replacement
8
replacement human
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!