Recent attention has been focused on the operative treatment of mid-shaft fractures of the clavicle. This study compares the in-vitro biomechanical properties of a pre-formed titanium clavicle plate (Acumed) to a Synthes 3.5 mm limited-contact dynamic-compression (LCDC) plate using a cadaveric osteotomy model. An osteotomy was performed on 7 pairs of human clavicles and were randomly plated with either a Synthes 3.5 mm LCDC stainless steel plate or an Acumed titanium pre-contoured clavicle plate. After plating, specimens were tested on an EnduraTEC material testing apparatus for axial compression and tension strength, as well as torsional strength in compression and tension. Biomechanical test results for plated specimens are reported for the LCDC plate and the Acumed plate, and the 2 plates are compared. This exploratory study supports investigations with larger sample sizes to determine if the Acumed pre-contoured plate differs from the LCDC plate in biomechanical properties and the clinical implications of such differences.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jse.2008.02.017 | DOI Listing |
Arch Orthop Trauma Surg
January 2025
The Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, 123, Ta Pei Road, Niao Sung Dist, Kaohsiung, Taiwan.
Introduction: The optimal management strategy for unstable distal clavicular fractures remains controversial. Recent studies on plate techniques have reported good-to-excellent outcomes with no serious complications. The questions are that: (1) Does the use of wire augmentation with locking plate in distal part (distal wire augmentation) reduce radiographic loss of reduction (RLOR) and get earlier bony union in distal clavicular fractures? (2) Which fixation methods are associated with a higher incidence of acromioclavicular (AC) joints arthritis or subluxation? We collected and analyzed clinical studies on different plate fixation methods for unstable fractures to identify the best surgical modality.
View Article and Find Full Text PDFOrthopadie (Heidelb)
January 2025
Deutsches Schulterzentrum, Atos Klinik München, Effnerstr. 38, 81925, München, Deutschland.
Fractures of the clavicle (Latin clavicula, little key), which mainly occur in young men, account for 2.6-4% of all fractures in adults [1]. Above the age of 65 years more clavicular fractures occur in women [1].
View Article and Find Full Text PDFBiomedicines
November 2024
Universidad Europea de Madrid, Department of Nursing, Faculty of Medicine, Health and Sports, 28670 Madrid, Spain.
While the flat bones of the face, most of the cranial bones, and the clavicles are formed directly from sheets of undifferentiated mesenchymal cells, most bones in the human body are first formed as cartilage templates. Cartilage is subsequently replaced by bone via a very tightly regulated process termed endochondral ossification, which is led by chondrocytes of the growth plate (GP). This process requires continuous communication between chondrocytes and invading cell populations, including osteoblasts, osteoclasts, and vascular cells.
View Article and Find Full Text PDFBMC Surg
January 2025
Department of orthopedics, Shanghai Pudong New Area People's Hospital, Shanghai, P.R. China.
Background: The incidence rate of subsequent refracture after removal of the implant in mid-shaft clavicle fracture patients is relatively high. This can lead to additional medical costs and cause doctor-patient dispute. This study tries to introduce a new method to predict the refracture risk of the clavicle after hardware removal.
View Article and Find Full Text PDFWorld J Orthop
December 2024
Department of Orthopedic Surgery, King Saud Medical City, Riyadh 00966, Saudi Arabia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!