The influence of Young's modulus of loaded implants on bone remodeling: an experimental and numerical study in the goat knee.

J Biomed Mater Res A

Department of Prosthetic Dentistry/BIOMAT Research Group, School of Dentistry, Oral Pathology and Maxillofacial Surgery, Katholieke Universiteit Leuven, Belgium.

Published: September 2009

The aim of this study was to examine the influence of the Young's modulus of the implant material on the bone remodeling in a loaded condition. A combined animal experimental and computational study was set up. The animal experimental group comprised of 16 Saanen goats, each receiving one titanium implant (Young's modulus 110 GPa) and one high-density polyethylene (HDPE) implant (Young's modulus 1 GPa) in the left femoral condyle. Both types of implants received a titanium coating of 100 nm thickness. The implants protruded in the knee joint space and were directly weight bearing. The first group of eight goats was sacrificed after 6 weeks of loading and the second group of eight goats after 6 months of loading. The 16 femoral condyles with the 32 implants were prepared for microfocus computed tomography (micro-CT) scanning and histological sectioning. Three-dimensional trabecular bone parameters were calculated on the micro-CT images for the zones neck, middle, and apex of the implant. The percent of bone contact with the implant was measured on longitudinal histological sections. An axisymmetric finite element (FE) model was created to compare peri-implant bone strains and relative motion between a titanium and a HDPE implant for the experimental loading condition, and to assess the influence of different bone-implant interface (contact) conditions. From the statistical analysis of the 3D bone parameters, the difference between the titanium and HDPE implants was not significantly different (p > 0.05) between the zones (neck, middle, and apex) for both groups of goats. The implants could be considered in their entirety. After 6 weeks of loading, the PE implant presented lower connectivity and smaller marrow spaces in the circular region of 0-500 microm. In the region 500-1500 microm more bone volume was present for the PE implant. After 6 months, the PE implants showed more bone volume and thicker trabeculae than the titanium implants for the entire length of the implant. This effect was already present in the smallest region of interest, 0-500 microm. After 6 months more fibrous encapsulation was found around titanium implants. FE results demonstrated a substantial influence of the interface conditions on peri-implant strains and relative motion. For interface conditions that were representative for the early postoperative situation (involving press-fit and friction), differences in peri-implant bone strain distributions between titanium and HDPE could be related to the experimentally observed differences in amounts of bone and fibrous encapsulation. In contrast, differences in relative motion did not seem to play a role. Both the experimental and computational results suggest that implant stiffness can affect the peri-implant tissue response, which may be related to differences in peri-implant strains.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.32145DOI Listing

Publication Analysis

Top Keywords

young's modulus
16
relative motion
12
titanium hdpe
12
bone
10
implant
10
implants
9
influence young's
8
implants bone
8
bone remodeling
8
animal experimental
8

Similar Publications

Owing to the differences in sedimentary environments in the mining areas of western China, the mechanical properties of rocks in this region are significantly different from those in the central and eastern regions. Therefore, uniaxial cyclic loading-unloading tests were conducted on fine sandstone found in many roof rocks to study the evolution laws of mechanical properties, deformation characteristics, acoustic emission (AE) parameters, and energy under cyclic loading and unloading conditions. The accumulated residual strain, dissipative energy, acoustic emission cumulative ringing counts, and cumulative energy were introduced to characterize the degree of rock damage.

View Article and Find Full Text PDF

A stretchable, adhesive, and wearable hydrogel-based patches based on a bilayer PVA composite for online monitoring of sweat by artificial intelligence-assisted smartphones.

Talanta

January 2025

Department of Materials Science and Engineering, Sharif University of Technology, Azadi Avenue, Tehran, 14588-89694, Iran; Center for Bioscience and Technology, Institute for Convergence Science and Technology, Sharif University of Technology, Tehran, 14588-89694, Iran; Fraunhofer Institute for Manufacturing Technology and Advanced Materials, 28359, Bremen, Germany. Electronic address:

Real-time monitoring of sweat using wearable devices faces challenges such as limited adhesion, mechanical flexibility, and accurate detection. In this work, we present a stretchable, adhesive, bilayer hydrogel-based patch designed for continuous monitoring of sweat pH and glucose levels using AI-assisted smartphones. The patch is composed of a bottom PVA hydrogel layer functionalized with colorimetric reagents and glucose oxidase enzyme, while the top PVA-sucrose layer enhances skin adhesion and protects against air moisture.

View Article and Find Full Text PDF

Generic Elasticity of Thermal, Underconstrained Systems.

Phys Rev Lett

December 2024

CPT, CNRS, Aix Marseille Univ, Université de Toulon, (UMR 7332), Turing Center for Living Systems, Marseille, France.

Athermal (i.e., zero-temperature) underconstrained systems are typically floppy, but they can be rigidified by the application of external strain, which is theoretically well understood.

View Article and Find Full Text PDF

Hybrid additive manufacturing for Zn-Mg casting for biomedical application.

In Vitro Model

December 2024

Department of Industrial and Manufacturing Engineering, Pennsylvania State University, State College, University Park, PA USA.

Zinc (Zn) and its alloys have been the focus of recent materials and manufacturing research for orthopaedic implants due to their favorable characteristics including desirable mechanical strength, biodegradability, and biocompatibility. In this research, a novel process involving additive manufacturing (AM) augmented casting was employed to fabricate zinc-magnesium (Zn-0.8 Mg) artifacts with surface lattices composed of triply periodic minimal surfaces (TPMS), specifically gyroid.

View Article and Find Full Text PDF

Carbon-carbon (C/C) composites are attractive materials for high-speed flights and terrestrial atmospheric reentry applications due to their insulating thermal properties, thermal resistance, and high strength-to-weight ratio. It is important to understand the evolving structure-property correlations in these materials during pyrolysis, but the extreme laboratory conditions required to produce C/C composites make it difficult to quantify the properties . This work presents an atomistic modeling methodology to pyrolyze a crosslinked phenolic resin network and track the evolving thermomechanical properties of the skeletal matrix during simulated pyrolysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!