Collecting whole blood on filter paper simplifies the processing, transport, and storage of specimens used for the diagnosis of human immunodeficiency virus type 1 (HIV-1) and other tests. Specimens may be collected in tropical or rural areas with minimal facilities for handling specimens. To compare simulated tropical conditions with freezer storage, we examined the stability of HIV-1 DNA in dried blood spots (DBS) stored in humid heat and at -20 degrees C. DBS were created by spotting 50-microl aliquots of whole blood on 903 filter paper. DNA was extracted from DBS at baseline and after 2, 6, or 12 months of storage at -20 degrees C or at 37 degrees C with approximately 85% humidity. The DNA was tested undiluted or diluted using the Amplicor HIV-1 DNA PCR (Roche), version 1.5. Each reaction was scored positive, negative, or indeterminate based on optical density. Results were compared between storage conditions and over time. A total of 1,832 reactions from 916 DBS were analyzed, including 100 DBS at baseline, 418 stored at -20 degrees C, and 398 stored at 37 degrees C. A chi-square test showed fewer positive reactions for DBS stored at 37 degrees C (55%) than for those stored at -20 degrees C (78%) (P < 0.0001). Samples stored at -20 degrees C showed little change in the probability of detection of HIV-1 DNA over time; the odds ratio (OR) was 0.93 after storage for 1 year. Samples stored at 37 degrees C demonstrated a significant change in detection at 1 year (OR, 0.29). We conclude that exposure of DBS to 37 degrees C and high humidity impaired the recovery of HIV-1 DNA from DBS, whereas DNA recovery was preserved when DBS were stored frozen.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2546762PMC
http://dx.doi.org/10.1128/JCM.00359-08DOI Listing

Publication Analysis

Top Keywords

-20 degrees
24
hiv-1 dna
16
degrees
12
dbs stored
12
stored -20
12
stored degrees
12
dbs
9
human immunodeficiency
8
immunodeficiency virus
8
virus type
8

Similar Publications

: Chronic pain affects about 20% of total knee arthroplasty (TKA) patients, with high pain catastrophizing being a key predictor. Screening and addressing this modifiable factor may improve postoperative outcomes. : We aimed to compare the effectiveness of two preoperative home-based multimodal physical therapy interventions on pain catastrophizing in high-catastrophizing TKA patients.

View Article and Find Full Text PDF

This retrospective longitudinal outcome study comparing orthodontic extraction modalities, including extraction of maxillary first or second molars, aimed to compare the three-dimensional tooth movement of maxillary canines (C), premolars (P1, P2), and molars (M1, M2) in Class II division 1 malocclusion treatment with fixed appliances. A sample of 98 patients (mean age 13.20 ± 1.

View Article and Find Full Text PDF

Some calculated total blood count readings are investigated as novel additional readings to help with evaluation of personalized CAD patients' clinical management and prognosis. We aimed to investigate the association between readings such as NLR, MLR, PLR, NMR, LMR, MHR, SII, and SIRI and the severity of CAD in patients with SAP. This retrospective pilot study included 166 patients.

View Article and Find Full Text PDF

Fibre Optic Method for Detecting Oil Fluorescence in Marine Sediments.

Sensors (Basel)

December 2024

Department of Operational Oceanography, Maritime Institute, Gdynia Maritime University, ul. Roberta de Plelo 20, 80-848 Gdańsk, Poland.

The aim of this study is to verify the possibility of detecting oil in the bottom sediment using a fibre optic system. The presence of oil is assessed on excitation-emission spectra obtained from spectral fluorescence signals of the sediment sample. A factory spectrofluorometer coupled with an experimental fibre optic measurement system was used.

View Article and Find Full Text PDF

This article presents the results of experimental studies on the influence of the geometry of high-voltage plasma actuator electrodes on the change in flow in the boundary layer and their influence on the change in the lift coefficient. The plasma actuator used in the described experimental studies has a completely different structure. The experimental model of the plasma actuator uses a large mesh ground electrode and different geometries of the high-voltage electrodes, namely copper solid electrodes and mesh electrodes (the use of mesh electrodes, large GND and HV is a new solution).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!