In 50 cases with an end-diastolic zero flow or reverse flow all antenatal and perinatal abnormalities have been recorded. The fetal outcome was registered. The percentage of highly dystrophic newborns (percentile less than 5) was 88%. The perinatal mortality counted up to 16% and the percentage of congenital malformations (including chromosomal anomalies) was 12%. A reverse flow was registered in 4 cases. The perinatal mortality of those cases with reverse flow was 100%. In approx. one-quarter of those pregnancies and in 50% of the perinatally deceased newborns, there were no pathological or suspicious changes in the antepartal and/or subpartal CTG-recordings. The Duplex sonographical diagnosis of an end-diastolic zero flow/reverse flow, has a highly positive predictive value, whereas its sensitivity is low. It can be regarded as a very helpful parameter in clinical diagnosis, particularly as it is independent of borderline values. The correct choice of the high-pass wall filter (50-100 Hz) is important.

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-2008-1026313DOI Listing

Publication Analysis

Top Keywords

reverse flow
12
cases end-diastolic
8
perinatal mortality
8
flow
5
[doppler ultrasonography--perinatal
4
ultrasonography--perinatal data
4
cases
4
data cases
4
end-diastolic block
4
reverse
4

Similar Publications

Metabolic activity controls the emergence of coherent flows in microbial suspensions.

Proc Natl Acad Sci U S A

January 2025

Experimental Physics V, Department of Physics, University of Bayreuth, D-95447 Bayreuth, Germany.

Photosynthetic microbes have evolved and successfully adapted to the ever-changing environmental conditions in complex microhabitats throughout almost all ecosystems on Earth. In the absence of light, they can sustain their biological functionalities through aerobic respiration, and even in anoxic conditions through anaerobic metabolic activity. For a suspension of photosynthetic microbes in an anaerobic environment, individual cellular motility is directly controlled by its photosynthetic activity, i.

View Article and Find Full Text PDF

Cancer in pregnancy has an incidence of approximately 1:1000, and cases of sarcoma in pregnancy are rare, with only a few described in the literature. This case report describes a 32-year-old pregnant woman who noticed an approximately 3.0 cm nodule on her left flank in the second trimester of pregnancy.

View Article and Find Full Text PDF

Cilostazol has previously been shown to reduce liver steatosis and enhance hepatic perfusion. We investigated the effects of cilostazol after major hepatectomy in a steatotic rat model. Six weeks prior to surgery, Sprague-Dawley rats were fed with a high-fructose diet.

View Article and Find Full Text PDF

Futile recanalization hampers prognoses for ischemic stroke patients despite successful recanalization therapy. Allegedly, hypertension and reperfusion deficits contribute, but a better understanding is needed of how they interact and mediate disease outcome. We reassessed data from spontaneously hypertensive and normotensive Wistar-Kyoto rats (male, n = 6-7/group) that were subjected to two-hour embolic middle cerebral artery occlusion and thrombolysis in preclinical trials.

View Article and Find Full Text PDF

Proximal protection devices for carotid artery stenting - A benchtop assessment of flow reversal performance.

AJNR Am J Neuroradiol

January 2025

From the Department of Radiology (J.L., E.A.B., C.B., J.C., R.K., W.B., D.F.K), and Department of Neurologic Surgery (Y.C.S., R.K., W.B.), Mayo Clinic, Rochester, MN, United States; Department of Stroke Research (J.L.), Vall d'Hebron Research Institute, Barcelona, Spain; From the Global Institute of Future Technology (Y.L.), Shanghai Jiao Tong University, Shanghai, China; Department of Neurointerventional Radiology (J.C.), Bicetre University Hospital, Le Kremlin Bicetre, France.

Background And Purpose: Proximal protection devices, such as TransCarotid Artery Revascularization (TCAR, SilkRoad Medical, Sunnyvale), aim to yield better outcomes in carotid artery stenting (CAS) than distal protection devices by preventing plaque embolization to the brain. However, transfemoral catheters may not fully reverse flow from the external carotid artery (ECA) to the internal carotid artery (ICA). We assess a new balloon-sheath device, Femoral Flow Reversal Access for Carotid Artery Stenting (FFRACAS), for this purpose.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!