Implant placement in fresh extraction sockets and simultaneous osteotome sinus floor elevation: a case series.

Int J Periodontics Restorative Dent

Department of Oral Pathology, Nanoword Institute, School of Dental Medicine, University of Genova, Italy.

Published: June 2008

The purpose of this study was to evaluate the clinical success of implants placed in fresh extraction sockets with simultaneous maxillary sinus floor elevation using the osteotome technique. Twelve patients were included. All the patients required the extraction of a maxillary premolar--close to the maxillary sinus--and were scheduled for immediate implant placement. One experimental implant was placed per patient, with an 18-month follow-up period. The graft materials used in both sinus augmentation and peri-implant bone defects were a mixture of collagen gel and corticocancellous porcine bone particles. All implants were allowed to heal for 6 months prior to prosthetic rehabilitation. One of the 12 experimental implants failed because of an abscess during early healing. No implants failed after definitive prosthetic rehabilitation. No significant bone loss was detected at the final follow-up visit. The mean bone height before sinus elevation and implant placement was 7.8 mm. Eighteen months after surgery, the mean bone height was 12 mm. When adequately performed, the surgical procedure described in the present study--immediate implant placement and simultaneous sinus floor elevation--appears to be unproblematic and predictable in terms of clinical success.

Download full-text PDF

Source

Publication Analysis

Top Keywords

implant placement
16
sinus floor
12
fresh extraction
8
extraction sockets
8
sockets simultaneous
8
floor elevation
8
clinical success
8
prosthetic rehabilitation
8
implants failed
8
bone height
8

Similar Publications

Application of a semi-active robotic system for implant placement in atrophic posterior maxilla: a retrospective case series.

J Dent

January 2025

Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University. Electronic address:

Objective: The study aimed to evaluate the accuracy and safety of the semi-active robotic system for implant placement in atrophic posterior maxilla.

Methods: Patients underwent robot-assisted implant placement in atrophic posterior maxilla were identified and included. Cone-beam computed tomography (CBCT) was performed before surgery.

View Article and Find Full Text PDF

Prcis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).

Purpose: To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.

Methods: Multicenter, real-world, retrospective study.

View Article and Find Full Text PDF

Finite element modeling of clavicle fracture fixations: a systematic scoping review.

Med Biol Eng Comput

January 2025

Department of Orthopaedics, School of Medicine, Ruijin Hospital, Shanghai Jiao Tong University, Shanghai, China.

Finite element analysis has become indispensable for biomechanical research on clavicle fractures. This review summarized evidence regarding configurations and applications of finite element analysis in clavicle fracture fixation. Seventeen articles involving 22 clavicles were synthesized from CINAHL, Embase, IEEE Xplore, PubMed, Scopus, and Web of Science databases.

View Article and Find Full Text PDF

Purpose: To present a modified evisceration technique with a full-thickness horizontal sclerotomy and assess post-operative motility and long-term outcomes.

Methods: This is a retrospective chart review of patients who underwent evisceration with a single surgeon (TJM). The standard initial steps of evisceration were performed.

View Article and Find Full Text PDF

Purpose: Few studies have explored the bone response in dental implant sites prepared using a piezoelectric device, indicating moderate effectiveness in enhancing secondary stability and osteogenesis. This study seeks to expand our understanding of the changes in biological, clinical, and radiographic parameters, during the initial phases of osseointegration in sites prepared with piezoelectric surgery.

Materials And Methods: Two implant sites were prepared in the tibia of four minipigs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!