Of all the naturally occurring groundwater contaminants, arsenic is by far the most toxic. Any large-scale treatment strategy to remove arsenic from groundwater must take into consideration safe containment of the arsenic removed with no adverse ecological impact. Currently, 175 well-head community-based arsenic removal units are in operation in remote villages of the Indian subcontinent. Approximately 150,000 villagers collect arsenic-safe potable water everyday from these units. The continued safe operation of these units has amply demonstrated that use of regenerable arsenic-selective adsorbents is quite viable in remote locations. Upon exhaustion, the adsorbents are regenerated in a central facility by a few trained villagers and reused. The process of regeneration reduces the volume of disposable arsenic-laden solids by nearly 2 orders of magnitude. Finally, the arsenic-laden solids are contained on well-aerated coarse-sand filters with minimum arsenic leaching. This disposal technique is scientifically more appropriate than dumping arsenic-loaded adsorbents in the reducing environment of landfills as currently practiced in developed countries including the United States.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es702556tDOI Listing

Publication Analysis

Top Keywords

arsenic removal
8
safe containment
8
arsenic-laden solids
8
arsenic
6
removal groundwater
4
groundwater safe
4
containment rural
4
rural environment
4
environment validation
4
validation sustainable
4

Similar Publications

In Slovakia, there are a number of contaminated sites that have occurred due to intensive mining, mineral processing, metallurgical activities, chemical industry, fossil fuel combustion, and industrial agriculture in the past. This paper summarizes the occurrence, chemistry, toxicity, and mineralogy of arsenic species related to soil and water contamination in Slovakia. Four main localities with arsenic exposure were identified.

View Article and Find Full Text PDF

Determination of main influence mechanism of fulvic acid on arsenic removal by ferric chloride.

J Environ Sci (China)

July 2025

John A. Reif, Jr. Department of Civil and Environmental Engineering, New Jersey Institute of Technology, Newark, New Jersey 07102, USA.

In this study, synthetic wastewater containing 110 µg/L arsenate (As(V)), 0-20 mg/L fulvic acid (FA), and 0-12.3 mg/L phosphate was treated with 3 mg/L Fe. The mechanisms of FA and phosphate effects on As(V) removal by ferric chloride were determined using 0.

View Article and Find Full Text PDF

In situ arsenic immobilization by natural iron (oxyhydr)oxide precipitates in As-contaminated groundwater irrigation canals.

J Environ Sci (China)

July 2025

Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, School of Environmental Science and Engineering, Guangzhou University, Guangzhou 510006, China. Electronic address:

Arsenic-contaminated groundwater is widely used in agriculture. To meet the increasing demand for safe water in agriculture, an efficient and cost-effective method for As removal from groundwater is urgently needed. We hypothesized that Fe (oxyhydr)oxide (FeOOH) minerals precipitated in situ from indigenous Fe in groundwater may immobilize As, providing a solution for safely using As-contaminated groundwater in irrigation.

View Article and Find Full Text PDF

Synthesis mechanisms, property characterization, and environmental applications of biogenic FeS: A review.

Water Res

January 2025

Baohang Environment Co., LTD, Beijing 100070, China. Electronic address:

Iron sulfide (FeS) exhibits superior reactivity toward a wide range of contaminants, making it a promising candidate for environmental remediation in various media, including surface water, wastewater, soil, and groundwater. Driven by green and sustainable development principles, efficient, low-cost, and environmentally friendly biosynthesis has attracted considerable attention and has great environmental remediation potential. This review provides a comprehensive overview of the recent advances in biogenic FeS (bio-FeS), focusing on its synthesis mechanisms, performance characterization, and environmental applications.

View Article and Find Full Text PDF

Co-pyrolysis is an efficient approach for municipal sewage sludge (SS) treatment, facilitating the production of biochar and promoting the stabilization and removal of heavy metals, particularly when combined with chlorinated materials. This study explores the impact of pyrolysis temperatures (400 °C and 600 °C) and chlorinated additives (polyvinyl chloride (PVC) as an organic chloride source and ferric chloride (FeCl) as an inorganic chloride source) at 10% and 20% concentrations, on the yield, chemical speciation, leachability, and ecological risks of arsenic (As), chromium (Cr), and zinc (Zn) in biochar derived from SS. The results revealed that increasing the pyrolysis temperature from 400 to 600 °C significantly reduced biochar yield due to enhanced volatilization of organic components, as well as the removal of heavy metals in interaction with chlorinated materials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!