Correlation between ventricular flow field and valve closing sound of mechanical mitral prostheses.

J Artif Organs

Department of Mechanical Engineering, College of Engineering, Kanto Gakuin University, 1-50-1 Mutsuura-higashi, Yokohama, 236-8501, Japan.

Published: October 2008

The Jyros (JR) valve and the newer On-X and MIRA valves, all installed antianatomically, were compared with the St. Jude Medical (SJM) valve in the mitral position to study the effects of valve design differences on the down-stream flow field and the associated valve closing sound. The dynamic particle image velocimetry method utilizing a high-speed video flow visualization technique was used to map the velocity field, and wavelet analysis of the sound was used to find the correlation between the ventricular flow field and the valve closing sound. Based on the experimental data, the following general conclusions can be made. In the velocity field directly below the mitral valve, where the distinct characteristic differences of the valve designs will be evident, twin symmetrical circulations were observed due to the divergent nature of the flow generated by the two inclined half-disks with the valve installed in the anti-anatomical orientation; the SJM, the On-X, and the MIRA valves generated a centrally downward circulation that opposed the valve leaflet closing movement, and resulted in relatively loud valve closing sounds.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10047-008-0411-xDOI Listing

Publication Analysis

Top Keywords

valve closing
16
flow field
12
closing sound
12
valve
11
correlation ventricular
8
ventricular flow
8
field valve
8
on-x mira
8
mira valves
8
velocity field
8

Similar Publications

A Robust Normally Closed Pneumatic Valve for Integrated Microfluidic Flow Control.

Micromachines (Basel)

December 2024

Zepto Life Technology Inc., 1000 Westgate Drive, St. Paul, MN 55114, USA.

Accurate fluid management in microfluidic-based point-of-care testing (POCT) devices is critical. Fluids must be gated and directed in precise sequences to facilitate desired biochemical reactions and signal detection. Pneumatic valves are widely utilized for fluid gating due to their flexibility and simplicity.

View Article and Find Full Text PDF

Aims: Evidence regarding the safety of early discharge following transcatheter aortic valve implantation (TAVI) is limited. The aim of this study was to evaluate the safety of very early (<24) and early discharge (24-48 h) as compared to standard discharge (>48 h), supported by the implementation of a voice-based virtual assistant using artificial intelligence (AI) and natural language processing.

Methods And Results: Single-arm prospective observational study that included consecutive patients who underwent TAVI in a tertiary hospital in 2023 and were discharged under an AI follow-up programme.

View Article and Find Full Text PDF

Background: Timing of treatment of aortic stenosis (AS) is of key importance. AS severity is currently determined by transthoracic echocardiography (TTE) with a main focus on mean trans-aortic gradients. However, echocardiography has its limitations.

View Article and Find Full Text PDF

Factors associated with the time of glaucoma-related adverse events onset after pediatric cataract surgery and the preferred anti-glaucomatous surgical selection.

Int Ophthalmol

January 2025

Department of Ophthalmology and Visual Science, Eye and ENT Hospital, Shanghai Medical College, Fudan University, 83 Fenyang Road, Shanghai, 200031, China.

Purpose: To describe the clinical characteristics of glaucoma-related adverse events (GRAE) after pediatric cataract surgery. More importantly, to identify the factors associated with the time of GRAE onset and the preferred anti-glaucomatous surgical procedure for this disease.

Methods: Hospitalized medical records of patients who developed GRAE, which include glaucoma and glaucoma suspect, after pediatric cataract surgery (surgical age ≤ 14 years) between 1994 and 2021 were retrospectively reviewed.

View Article and Find Full Text PDF

Background: Left ventricular assist device (LVAD) has been widely used as an alternative treatment for heart failure, however, aortic regurgitation is a common complication in patients with LVAD support. And the O-A angle (the angle between LVAD outflow graft and the aorta) is considered as a vital factor associated with the function of aortic valve. To date, the biomechanical effect of the O-A angle on the aortic valve remains largely unknown.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!